UL D1531.5-hr Fire RatingFloor/CeilingLoad-BearingSTC 53
Steel JoistDesign
Steel Joist Floor/Ceiling — single layer Spray-applied fireproofing
UL-listed 1.5-hour fire-rated steel joist floor/ceiling assembly. Open-web steel joists at 48" o.c., single layer of Spray-applied fireproofing ceiling.
Cross-Section Diagram
Legend
1Floor covering(varies)
22" concrete on steel deck(2")
3Open-web steel joists at 48" o.c.(14.0")
4Spray-applied fireproofing(1-1/2")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 53
Load Bearing
Yes
Total Thickness
17"
Applicable Codes
IRC R302.1
Construction Summary
Open-web steel joists at 48" o.c., single layer of Spray-applied fireproofing ceiling
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.