Home / Assemblies / UL D156
UL D1561.5-hr Fire RatingFloor/CeilingLoad-BearingSTC 52
Steel JoistDesign

Steel Joist Floor/Ceiling — 2 layers Spray-applied fireproofing

UL-listed 1.5-hour fire-rated steel joist floor/ceiling assembly. Open-web steel joists at 48" o.c., 2 layers of Spray-applied fireproofing ceiling.

Cross-Section Diagram

12345FLOOR/CEILING ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
1Floor covering(varies)
23" concrete on steel deck(3")
3Open-web steel joists at 48" o.c.(14.0")
4Spray-applied fireproofing(1-1/2")
5Spray-applied fireproofing(1-1/2")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 52
Load Bearing
Yes
Total Thickness
18.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
D156
Assembly Type
Floor/Ceiling
Test Standard
ASTM E119
Construction Group
Non-Combustible
Number of Layers
5 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722IRC R302.1

Construction Summary

Open-web steel joists at 48" o.c., 2 layers of Spray-applied fireproofing ceiling

Material Layers

LayerMaterialThickness
1Floor coveringvaries
23" concrete on steel deck3"
3Open-web steel joists at 48" o.c.14.0"
4Spray-applied fireproofing1-1/2"
5Spray-applied fireproofing1-1/2"

Important Notice