UL D1704-hr Fire RatingFloor/CeilingLoad-BearingSTC 55
Steel JoistMulti-Layer GypsumFiberglass BattHigh STCDesign
Steel Joist Floor/Ceiling — 4 layers 5/8" Type C gypsum board
UL-listed 4-hour fire-rated steel joist floor/ceiling assembly. Open-web steel joists at 48" o.c. with R-19 fiberglass batt, 4 layers of 5/8" Type C gypsum board ceiling.
Cross-Section Diagram
Legend
1Floor covering(varies)
22-1/2" lightweight concrete on steel deck(2-1/2")
3Open-web steel joists at 48" o.c.(14.0")
4R-19 fiberglass batt
55/8" Type C gypsum board(5/8")
65/8" Type C gypsum board(5/8")
75/8" Type C gypsum board(5/8")
85/8" Type C gypsum board(5/8")
Specifications
Fire Rating
4-Hour
STC Rating
STC 55
Load Bearing
Yes
Total Thickness
18"
Applicable Codes
IBC 2024 Table 722.1NFPA 5000
Construction Summary
Open-web steel joists at 48" o.c. with R-19 fiberglass batt, 4 layers of 5/8" Type C gypsum board ceiling
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.