Home / Assemblies / UL D171
UL D1714-hr Fire RatingFloor/CeilingLoad-BearingSTC 38
Steel JoistDesign

Steel Joist Floor/Ceiling — 4 layers Spray-applied fireproofing

UL-listed 4-hour fire-rated steel joist floor/ceiling assembly. Open-web steel joists at 48" o.c., 4 layers of Spray-applied fireproofing ceiling.

Cross-Section Diagram

1234567FLOOR/CEILING ASSEMBLYSECTION · NOT TO SCALE7 LAYERSsee legend for ① ② ③
Legend
1Floor covering(varies)
22-1/2" lightweight concrete on steel deck(2-1/2")
3Open-web steel joists at 48" o.c.(14.0")
4Spray-applied fireproofing(1-1/2")
5Spray-applied fireproofing(1-1/2")
6Spray-applied fireproofing(1-1/2")
7Spray-applied fireproofing(1-1/2")

Specifications

Fire Rating
4-Hour
STC Rating
STC 38
Load Bearing
Yes
Total Thickness
21.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
D171
Assembly Type
Floor/Ceiling
Test Standard
ASTM E119
Construction Group
Non-Combustible
Number of Layers
7 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2021 §722

Construction Summary

Open-web steel joists at 48" o.c., 4 layers of Spray-applied fireproofing ceiling

Material Layers

LayerMaterialThickness
1Floor coveringvaries
22-1/2" lightweight concrete on steel deck2-1/2"
3Open-web steel joists at 48" o.c.14.0"
4Spray-applied fireproofing1-1/2"
5Spray-applied fireproofing1-1/2"
6Spray-applied fireproofing1-1/2"
7Spray-applied fireproofing1-1/2"

Important Notice