UL U1133-hr Fire RatingWallLoad-BearingSTC 50
Wood StudMulti-Layer GypsumLoad-Bearing WallDesign
Wood Stud Wall — 2 layers 1/2" Type X
UL-listed 3-hour fire-rated wood stud wall assembly. 2x4 wood studs at 16" o.c., 2 layers of 1/2" Type X gypsum board each side.
Cross-Section Diagram
Legend
11/2" Type X gypsum board(1/2")
21/2" Type X gypsum board(1/2")
32x4 wood studs at 16" o.c.(3.5")
41/2" Type X gypsum board(1/2")
51/2" Type X gypsum board(1/2")
Specifications
Fire Rating
3-Hour
STC Rating
STC 50
Load Bearing
Yes
Total Thickness
5.5"
Applicable Codes
IBC 2024 Table 722.1IRC R302.1
Construction Summary
2x4 wood studs at 16" o.c., 2 layers of 1/2" Type X gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.