UL U1153-hr Fire RatingWallLoad-BearingSTC 45
Wood StudMulti-Layer GypsumFiberglass BattLoad-Bearing WallDesign
Wood Stud Wall — 3 layers 5/8" Type X
UL-listed 3-hour fire-rated wood stud wall assembly. 2x4 wood studs at 16" o.c. with R-13 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
42x4 wood studs at 16" o.c.(3.5")
5R-13 fiberglass batt
65/8" Type X gypsum board(5/8")
75/8" Type X gypsum board(5/8")
85/8" Type X gypsum board(5/8")
Specifications
Fire Rating
3-Hour
STC Rating
STC 45
Load Bearing
Yes
Total Thickness
7.25"
Applicable Codes
IRC R302.1IBC 2024 §722IBC 2024 Table 722.1
Construction Summary
2x4 wood studs at 16" o.c. with R-13 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.