UL U2021.5-hr Fire RatingWallSTC 62
Steel StudMulti-Layer GypsumResilient ChannelPartitionHigh STCDesign
Steel Stud Wall — 2 layers 5/8" Type X on resilient channels
UL-listed 1.5-hour fire-rated steel stud wall assembly. 3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
3Resilient channels at 24" o.c.(7/8")
43-5/8" steel studs at 24" o.c.(3.625")
55/8" Type X gypsum board(5/8")
65/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 62
Load Bearing
No
Total Thickness
7"
Applicable Codes
IBC 2024 Table 722.1
Construction Summary
3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.