Home / Assemblies / UL U325
UL U3253-hr Fire RatingWallSTC 50
Steel StudMulti-Layer GypsumPartitionDesign

Shaft Wall — 2 layers 1" Type C

UL-listed 3-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c., 2 layers of 1" Shaftliner gypsum board each side.

Cross-Section Diagram

123456.50"WALL ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
11" Shaftliner gypsum board(1")
21" Shaftliner gypsum board(1")
32-1/2" CT studs at 24" o.c.(2.5")
41" Shaftliner gypsum board(1")
51" Shaftliner gypsum board(1")

Specifications

Fire Rating
3-Hour
STC Rating
STC 50
Load Bearing
No
Total Thickness
6.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U325
Assembly Type
Wall
Test Standard
UL 263
Construction Group
Concrete/Masonry
Number of Layers
5 layers

Applicable Codes

IRC R302.1IBC 2021 §722IBC 2021 Table 722.1

Construction Summary

2-1/2" CT studs at 24" o.c., 2 layers of 1" Shaftliner gypsum board each side

Material Layers

LayerMaterialThickness
11" Shaftliner gypsum board1"
21" Shaftliner gypsum board1"
32-1/2" CT studs at 24" o.c.2.5"
41" Shaftliner gypsum board1"
51" Shaftliner gypsum board1"