B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Home / Assemblies / UL X207
UL X2071.5-hr Fire RatingBeamLoad-Bearing
Design

Wood Beam — Intumescent coating

UL-listed 1.5-hour fire-rated wood beam assembly. LVL beam with Intumescent coating, 1.5-hour fire rating.

Cross-Section Diagram

12BEAM PROTECTIONSECTION · NOT TO SCALE2 LAYERSsee legend for ① ② ③
Legend
1LVL beam(14")
2Intumescent coating(0.095")

Specifications

Fire Rating
1.5-Hour
Load Bearing
Yes
Total Thickness
14.19"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
X207
Assembly Type
Beam
Test Standard
CAN/ULC-S101
Construction Group
Non-Combustible
Number of Layers
2 layers

Applicable Codes

IBC 2024 §722IBC 2021 §722

Construction Summary

LVL beam with Intumescent coating, 1.5-hour fire rating

Material Layers

LayerMaterialThickness
1LVL beam14"
2Intumescent coating0.095"

Important Notice

This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.