Portland cement acceptance per AASHTO M 85 (Types I, II, V) or M 240 (blended cements). Required tests: fineness (AASHTO T 153), time of setting (AASHTO T 131), compressive strength (AASHTO T 106), soundness (AASHTO T 107), and chemical analysis (AASHTO T 105). Supplementary cementitious materials: fly ash (AASHTO M 295), slag cement (AASHTO M 302), silica fume (AASHTO M 307). NJDOT cement testing at source with Certificates of Compliance.
References: AASHTO current edition, NJ Standard Specifications, FHWA Technical Advisories, and applicable federal regulations (23 CFR). Contractors shall maintain current copies of all referenced standards on the project site.
Source: NJDOT Materials Testing Manual, 2024 Edition. Pages 7–8 of 25.