Geosynthetics

M-601Geotextile and Geosynthetic Testing

NY · 2024 Standard SpecificationsBook pages 2324View official source ↗

Geotextile testing per AASHTO M 288 for separation, filtration, stabilization, and drainage applications. Required tests: grab tensile strength (AASHTO T 190), puncture resistance, permittivity, AOS (apparent opening size). Geogrid testing: tensile strength at 2% and 5% strain per GRI-GG1. NYSDOT uses the Qualified Products List for approved geosynthetic products. Field installation per manufacturer specifications with minimum overlap of 12 inches for separation applications.

References: AASHTO current edition, NY Standard Specifications, FHWA Technical Advisories, and applicable federal regulations (23 CFR). Contractors shall maintain current copies of all referenced standards on the project site.

Source: NYSDOT Materials Testing Manual, 2024 Edition. Pages 2324 of 25.