2-5Superelevation

UT · 2024 Standard SpecificationsBook pages 1314View official source ↗

Superelevation design follows AASHTO Method 5 (current UT policy). Distribution tables are provided for maximum superelevation rates of 6% (rural) and 4% (urban/low-speed). Superelevation runoff length is based on design speed and number of lanes rotated. The axis of rotation is typically the centerline for undivided highways and the median edge for divided highways. Superelevation transitions through intersections require special treatment per Chapter 3.

All work under this section shall comply with UDOT current standards and applicable AASHTO, ASTM, and federal requirements. The Engineer has authority to accept or reject materials and workmanship that do not conform to the specifications.

Source: UDOT Highway Design Manual, 2024 Edition. Pages 1314 of 37.