UL U1241-hr Fire RatingWallLoad-BearingSTC 56
Wood StudGypsum BoardMineral WoolResilient ChannelLoad-Bearing WallHigh STCDesign

Wood Stud Wall — single layer 5/8" Type X on resilient channels

UL-listed 1-hour fire-rated wood stud wall assembly. 2x4 wood studs at 24" o.c. with R-21 mineral wool batt, single layer of 5/8" Type X gypsum board each side on resilient channels.

Cross-Section Diagram

123457.13"WALL ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
2Resilient channels at 24" o.c.(7/8")
32x4 wood studs at 24" o.c.(3.5")
4R-21 mineral wool batt
55/8" Type X gypsum board(5/8")

Specifications

Fire Rating
1-Hour
STC Rating
STC 56
Load Bearing
Yes
Total Thickness
5.625"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U124
Assembly Type
Wall
Test Standard
CAN/ULC-S101
Construction Group
Light Frame
Number of Layers
5 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722NFPA 5000

Construction Summary

2x4 wood studs at 24" o.c. with R-21 mineral wool batt, single layer of 5/8" Type X gypsum board each side on resilient channels

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
2Resilient channels at 24" o.c.7/8"
32x4 wood studs at 24" o.c.3.5"
4R-21 mineral wool batt
55/8" Type X gypsum board5/8"