UL U1481-hr Fire RatingWallLoad-BearingSTC 45
Wood StudGypsum BoardFiberglass BattLoad-Bearing WallDesign
Wood Stud Wall — single layer 5/8" Type X
UL-listed 1-hour fire-rated wood stud wall assembly. 2x6 wood studs at 16" o.c. with R-19 fiberglass batt, single layer of 5/8" Type X gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
22x6 wood studs at 16" o.c.(5.5")
3R-19 fiberglass batt
45/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 45
Load Bearing
Yes
Total Thickness
6.75"
Applicable Codes
NFPA 5000IBC 2024 §722IBC 2021 §722
Construction Summary
2x6 wood studs at 16" o.c. with R-19 fiberglass batt, single layer of 5/8" Type X gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.