UL U1393-hr Fire RatingWallLoad-BearingSTC 62
Wood StudMulti-Layer GypsumResilient ChannelLoad-Bearing WallHigh STCDesign
Wood Stud Wall — 3 layers 5/8" Type X on resilient channels
UL-listed 3-hour fire-rated wood stud wall assembly. 2x4 wood studs at 24" o.c., 3 layers of 5/8" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
4Resilient channels at 24" o.c.(7/8")
52x4 wood studs at 24" o.c.(3.5")
65/8" Type X gypsum board(5/8")
75/8" Type X gypsum board(5/8")
85/8" Type X gypsum board(5/8")
Specifications
Fire Rating
3-Hour
STC Rating
STC 62
Load Bearing
Yes
Total Thickness
8.125"
Applicable Codes
IBC 2021 §722
Construction Summary
2x4 wood studs at 24" o.c., 3 layers of 5/8" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.