UL U1741-hr Fire RatingWallLoad-BearingSTC 33
Wood StudGypsum BoardLoad-Bearing WallDesign
Wood Stud Wall — single layer 5/8" Type C
UL-listed 1-hour fire-rated wood stud wall assembly. 2x6 wood studs at 24" o.c., single layer of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
22x6 wood studs at 24" o.c.(5.5")
35/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 33
Load Bearing
Yes
Total Thickness
6.75"
Applicable Codes
IBC 2021 Table 722.1IRC R302.1
Construction Summary
2x6 wood studs at 24" o.c., single layer of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.