UL U2251.5-hr Fire RatingWallSTC 48
Steel StudGypsum BoardMineral WoolPartitionDesign
Steel Stud Wall — single layer 1/2" Type X
UL-listed 1.5-hour fire-rated steel stud wall assembly. 3-5/8" steel studs at 16" o.c. with R-15 mineral wool batt, single layer of 1/2" Type X gypsum board each side.
Cross-Section Diagram
Legend
11/2" Type X gypsum board(1/2")
23-5/8" steel studs at 16" o.c.(3.625")
3R-15 mineral wool batt
41/2" Type X gypsum board(1/2")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 48
Load Bearing
No
Total Thickness
4.625"
Applicable Codes
IBC 2021 Table 722.1
Construction Summary
3-5/8" steel studs at 16" o.c. with R-15 mineral wool batt, single layer of 1/2" Type X gypsum board each side
Material Layers