UL U2343-hr Fire RatingWallLoad-BearingSTC 60
Steel StudMulti-Layer GypsumResilient ChannelLoad-Bearing WallHigh STCDesign
Steel Stud Wall — 2 layers 1/2" Type X on resilient channels
UL-listed 3-hour fire-rated steel stud wall assembly. 3-5/8" steel studs at 16" o.c., 2 layers of 1/2" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
11/2" Type X gypsum board(1/2")
21/2" Type X gypsum board(1/2")
3Resilient channels at 24" o.c.(7/8")
43-5/8" steel studs at 16" o.c.(3.625")
51/2" Type X gypsum board(1/2")
61/2" Type X gypsum board(1/2")
Specifications
Fire Rating
3-Hour
STC Rating
STC 60
Load Bearing
Yes
Total Thickness
6.5"
Applicable Codes
IRC R302.1IBC 2021 Table 722.1
Construction Summary
3-5/8" steel studs at 16" o.c., 2 layers of 1/2" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.