UL U2501.5-hr Fire RatingWallSTC 53
Steel StudMulti-Layer GypsumResilient ChannelPartitionDesign

Steel Stud Wall — 2 layers 5/8" Type X on resilient channels

UL-listed 1.5-hour fire-rated steel stud wall assembly. 2-1/2" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels.

Cross-Section Diagram

1234565.88"WALL ASSEMBLYSECTION · NOT TO SCALE6 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
3Resilient channels at 24" o.c.(7/8")
42-1/2" steel studs at 24" o.c.(2.5")
55/8" Type X gypsum board(5/8")
65/8" Type X gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 53
Load Bearing
No
Total Thickness
5.875"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U250
Assembly Type
Wall
Test Standard
UL 263
Construction Group
Light Frame
Number of Layers
6 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722NFPA 5000

Construction Summary

2-1/2" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
25/8" Type X gypsum board5/8"
3Resilient channels at 24" o.c.7/8"
42-1/2" steel studs at 24" o.c.2.5"
55/8" Type X gypsum board5/8"
65/8" Type X gypsum board5/8"

Important Notice