UL U2711.5-hr Fire RatingWallSTC 45
Steel StudGypsum BoardFiberglass BattPartitionDesign
Steel Stud Wall — single layer 5/8" Type X
UL-listed 1.5-hour fire-rated steel stud wall assembly. 6" steel studs at 24" o.c. with R-11 fiberglass batt, single layer of 5/8" Type X gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
26" steel studs at 24" o.c.(6.0")
3R-11 fiberglass batt
45/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 45
Load Bearing
No
Total Thickness
7.25"
Applicable Codes
IBC 2021 §722IBC 2021 Table 722.1IBC 2024 §722
Construction Summary
6" steel studs at 24" o.c. with R-11 fiberglass batt, single layer of 5/8" Type X gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.