B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Home / Assemblies / UL U275
UL U2751.5-hr Fire RatingWallSTC 43
Steel StudMulti-Layer GypsumPartitionDesign

Steel Stud Wall — 2 layers 5/8" Type C

UL-listed 1.5-hour fire-rated steel stud wall assembly. 6" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side.

Cross-Section Diagram

123458.50"WALL ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
36" steel studs at 24" o.c.(6.0")
45/8" Type C gypsum board(5/8")
55/8" Type C gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 43
Load Bearing
No
Total Thickness
8.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U275
Assembly Type
Wall
Test Standard
UL 263
Construction Group
Light Frame
Number of Layers
5 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2024 §722IBC 2024 Table 722.1

Construction Summary

6" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type C gypsum board5/8"
25/8" Type C gypsum board5/8"
36" steel studs at 24" o.c.6.0"
45/8" Type C gypsum board5/8"
55/8" Type C gypsum board5/8"

Important Notice

This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.