UL U2813-hr Fire RatingWallLoad-BearingSTC 48
Steel StudMulti-Layer GypsumFiberglass BattLoad-Bearing WallDesign
Steel Stud Wall — 2 layers 5/8" Type C
UL-listed 3-hour fire-rated steel stud wall assembly. 6" steel studs at 24" o.c. with R-19 fiberglass batt, 2 layers of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
36" steel studs at 24" o.c.(6.0")
4R-19 fiberglass batt
55/8" Type C gypsum board(5/8")
65/8" Type C gypsum board(5/8")
Specifications
Fire Rating
3-Hour
STC Rating
STC 48
Load Bearing
Yes
Total Thickness
8.5"
Applicable Codes
IBC 2024 Table 722.1NFPA 5000IRC R302.1
Construction Summary
6" steel studs at 24" o.c. with R-19 fiberglass batt, 2 layers of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.