UL U2951.5-hr Fire RatingWallSTC 47
Steel StudGypsum BoardResilient ChannelPartitionDesign
Steel Stud Wall — single layer 5/8" Type X on resilient channels
UL-listed 1.5-hour fire-rated steel stud wall assembly. 6" steel studs at 16" o.c., single layer of 5/8" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
2Resilient channels at 24" o.c.(7/8")
36" steel studs at 16" o.c.(6.0")
45/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 47
Load Bearing
No
Total Thickness
8.125"
Applicable Codes
IBC 2021 Table 722.1IRC R302.1
Construction Summary
6" steel studs at 16" o.c., single layer of 5/8" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.