UL U3191.5-hr Fire RatingWallSTC 55
Steel StudGypsum BoardFiberglass BattResilient ChannelPartitionHigh STCDesign
Shaft Wall — single layer 1" Type C on resilient channels
UL-listed 1.5-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c. with R-11 fiberglass batt, single layer of 1" Shaftliner gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
11" Shaftliner gypsum board(1")
2Resilient channels at 24" o.c.(7/8")
32-1/2" CT studs at 24" o.c.(2.5")
4R-11 fiberglass batt
51" Shaftliner gypsum board(1")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 55
Load Bearing
No
Total Thickness
5.375"
Applicable Codes
IBC 2024 Table 722.1NFPA 5000IBC 2021 Table 722.1
Construction Summary
2-1/2" CT studs at 24" o.c. with R-11 fiberglass batt, single layer of 1" Shaftliner gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.