UL U3221.5-hr Fire RatingWallSTC 62
Steel StudMulti-Layer GypsumMineral WoolPartitionHigh STCDesign
Shaft Wall — 2 layers 5/8" Type X
UL-listed 1.5-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 2 layers of 5/8" Type X gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
32-1/2" CT studs at 24" o.c.(2.5")
4R-8 mineral wool
55/8" Type X gypsum board(5/8")
65/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 62
Load Bearing
No
Total Thickness
5"
Applicable Codes
IBC 2021 §722IBC 2024 §722
Construction Summary
2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 2 layers of 5/8" Type X gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.