B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Home / Assemblies / UL U322
UL U3221.5-hr Fire RatingWallSTC 62
Steel StudMulti-Layer GypsumMineral WoolPartitionHigh STCDesign

Shaft Wall — 2 layers 5/8" Type X

UL-listed 1.5-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 2 layers of 5/8" Type X gypsum board each side.

Cross-Section Diagram

1234566.50"WALL ASSEMBLYSECTION · NOT TO SCALE6 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
32-1/2" CT studs at 24" o.c.(2.5")
4R-8 mineral wool
55/8" Type X gypsum board(5/8")
65/8" Type X gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 62
Load Bearing
No
Total Thickness
5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U322
Assembly Type
Wall
Test Standard
CAN/ULC-S101
Construction Group
Concrete/Masonry
Number of Layers
6 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722

Construction Summary

2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 2 layers of 5/8" Type X gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
25/8" Type X gypsum board5/8"
32-1/2" CT studs at 24" o.c.2.5"
4R-8 mineral wool
55/8" Type X gypsum board5/8"
65/8" Type X gypsum board5/8"

Important Notice