Home / Assemblies / UL U344
UL U3443-hr Fire RatingWallSTC 62
Steel StudMulti-Layer GypsumFiberglass BattResilient ChannelPartitionHigh STCDesign

Shaft Wall — 3 layers 5/8" Type X on resilient channels

UL-listed 3-hour fire-rated shaft wall assembly. 3-5/8" CT studs at 24" o.c. with R-11 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side on resilient channels.

Cross-Section Diagram

1234567899.75"WALL ASSEMBLYSECTION · NOT TO SCALE9 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
4Resilient channels at 24" o.c.(7/8")
53-5/8" CT studs at 24" o.c.(3.625")
6R-11 fiberglass batt
75/8" Type X gypsum board(5/8")
85/8" Type X gypsum board(5/8")
95/8" Type X gypsum board(5/8")

Specifications

Fire Rating
3-Hour
STC Rating
STC 62
Load Bearing
No
Total Thickness
8.25"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U344
Assembly Type
Wall
Test Standard
UL 263
Construction Group
Concrete/Masonry
Number of Layers
9 layers

Applicable Codes

IRC R302.1

Construction Summary

3-5/8" CT studs at 24" o.c. with R-11 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side on resilient channels

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
25/8" Type X gypsum board5/8"
35/8" Type X gypsum board5/8"
4Resilient channels at 24" o.c.7/8"
53-5/8" CT studs at 24" o.c.3.625"
6R-11 fiberglass batt
75/8" Type X gypsum board5/8"
85/8" Type X gypsum board5/8"
95/8" Type X gypsum board5/8"