1061.11Chain Link Fence Gate

DE · 2025 Standard SpecificationsBook pages 731732View official source ↗

FENCE SECTION 1061 721 H. Vinyl coating:

1.When required by the contract, vinyl coat all chain link fence materials in accordance with

AASHTO M181 Type IV Class A .

1061.12Right -of-Way Fence Gate

A.Gate frame:
1.Conforming to the requirements of AASHTO M181.
2.Provide corners made of heavy malleable iron or pressed steel fittings, securely riveted or

welded.

3.Paint the welds with aluminum base or zinc base paint.
B.Woven wire fencing - Provide woven wire fencing or woven wire fabric made of #9 -gage

galvanized wire conforming to the requirements of AASHTO M279, Grade 60, Type Z, Class 3 coating.

C.Upper hinge – AASHTO M181.
D.Lower hinge – AASHTO M181.
E.Stretcher bar – AASHTO M181.
F.Stretcher bar band – AASHTO M181.
G.Locking device – AASHTO M181.

CONDUIT SECTION 1062 722 SECTION 1062 — CONDUIT

1062.1Material Requirements.

Provide conduit, sweeps, end caps, conduit bodies, conduit hangers, bushings, and all applicable appurtenances of compatible materials in accordance with the contract and these requirements.

A.Galvanized Steel Conduit:
1.Hot-dipped galvanized.
2.Conform to the requirements of ANSI C80.1, UL -6 and UL -514B.
3.Conform to the NEC 2011, Article 344.
4.UL listed.
B.HDPE SDR 13.5 Conduit:
1.Confor m to N EC 2017, Article 353.
2.For fiber optic conduit, paint in white letters longitudinally, “DelDOT traffic fiber optic cable.”
3.For lighting conduit, paint in white letters longitudinally, “DelDOT lighting cable.”
4.For traffic signal conduit, paint in white letters longitudinally, “DelDOT traffic signal cable.”
5.UL listed .
C.Schedule 80 PVC Conduit:
1.Conform to ASTM D2665.
2.Conform to NEC 201 7, Article 352.
3.Conform to ASTM D1785.
4.Conform to U.L. Standard 651 specifications for conduit.
5.Conform to U.L. Standard 614b specifications for fittings.
6.For fiber optic conduit, paint in white letters longitudinally, “DelDOT traffic fiber optic cable .”
7.For lighting conduit, paint in white letters longitudinally, “DelDOT lighting cable .”
8.For traffic signal conduit, paint in white letters longitudinally, “DelDOT traffic signal cable .”
9.UL listed .
D.Flexible Metallic Liquid Tight Conduit:
1.Conform to the NEC 2017, Article 350.
2.UL listed.
E.Nonmetallic Pole Riser Shield with Belled Ends:
1.Rural utility service (RUS) listed.
2.Conform to NEMA TC -19 specifications.
3.Conform to NEC 2017, Article 352.
F.Conduit Hangers: