Home / Calculators / Stair Layout Calculator

Stair Layout Calculator

Calculate stair geometry including number of risers, riser height, tread depth, total run, and stringer length. Reference: IBC 1011.5 / IRC R311.7

Limits and citations below follow the selected code

Floor-to-floor height (e.g., 108" = 9 ft)

Typically 7-7.75" (max residential)

Minimum 10" residential

Minimum 36" residential

Typically 0.75"-1.25"; not required when the tread is 11" or deeper

Measured vertically from the nosing line. Minimum 80" (6'-8")

Results

Number of Risers

14

Actual Riser Height

7 11/16"

7.714"

Number of Treads

13

Total Run

10'-10"

130.00"

Stringer Length

14'-1"

169.01"

Code Compliance

Riser ≤ 7.75"7 11/16" actual · IRC R311.7
Tread ≥ 10"10" actual · IRC R311.7
Width ≥ 36"36" actual · IRC R311.7
Headroom ≥ 80" (6'-8")6'-8" actual · IRC R311.7
Nosing 3/4"–1 1/4" (required)1" projection · IRC R311.7
Rise between landings ≤ 12'-7"9'-0" total rise · IRC R311.7

2R + T Comfort Rule (should be 24"-25")

2 × 7.71" + 10` = 25.43` - Not in ideal range

Code Reference

IBC 1011.5 / IRC R311.7 – Stair Design. All stairs must comply with riser height, tread depth, and width requirements.

Disclaimer: This calculator is for reference only. Always verify with your local building department.