Stair Layout Calculator
Calculate stair geometry including number of risers, riser height, tread depth, total run, and stringer length. Reference: IBC 1011.5 / IRC R311.7
Limits and citations below follow the selected code
Floor-to-floor height (e.g., 108" = 9 ft)
Typically 7-7.75" (max residential)
Minimum 10" residential
Minimum 36" residential
Typically 0.75"-1.25"; not required when the tread is 11" or deeper
Measured vertically from the nosing line. Minimum 80" (6'-8")
Results
Number of Risers
14
Actual Riser Height
7 11/16"
7.714"
Number of Treads
13
Total Run
10'-10"
130.00"
Stringer Length
14'-1"
169.01"
Code Compliance
2R + T Comfort Rule (should be 24"-25")
2 × 7.71" + 10` = 25.43` - Not in ideal range
Code Reference
IBC 1011.5 / IRC R311.7 – Stair Design. All stairs must comply with riser height, tread depth, and width requirements.
Disclaimer: This calculator is for reference only. Always verify with your local building department.