Smoke & Carbon Monoxide Alarm Placement — Where the Code Puts Them
Smoke alarm placement in a dwelling is a fixed list: each bedroom, outside each sleeping area, and every story. Carbon monoxide alarms attach to the same permit triggers whenever the home has fuel-fired appliances or an attached garage.
Smoke and carbon monoxide alarm placement — IRC 2021 R314 / R315.Open full diagram →
Requirement
Model Code Standard
Section
Smoke alarms — in bedrooms
One in each sleeping room
IRC R314.3
Smoke alarms — outside bedrooms
One outside each separate sleeping area, in the immediate vicinity of the bedrooms
IRC R314.3
Smoke alarms — every story
At least one per story including basements and habitable attics
IRC R314.3
Interconnection & power
Hardwired with battery backup and interconnected so all sound together; listed wireless interconnection allowed
IRC R314.4, R314.5
CO alarms — where
Outside each separate sleeping area, and required when the dwelling has fuel-fired appliances or an attached garage; in bedrooms when a fuel-fired appliance is in the bedroom or its bathroom
IRC R315.2, R315.3
Alterations trigger
Interior alterations, repairs, or additions requiring a permit bring the whole dwelling up to smoke/CO alarm requirements (battery-only allowed where no wiring access)
IRC R314.2.2, R315.2.2
Kitchen/bath spacing
Ionization alarms not within 20 ft of a permanent cooking appliance (10 ft with a silencing feature); photoelectric alarms not within 6 ft; not within 3 ft of bath doors with tub/shower
IRC R314.3.1
Worth knowing
The alterations trigger surprises homeowners: a simple permitted remodel means alarms in every bedroom of a 1970s house.
NFPA 72 governs installation details the IRC references — ceiling placement, distance from walls, and sloped-ceiling rules come from there.
Many states layer their own CO statutes on top of the IRC, including rental-property requirements.
Combination smoke/CO units are permitted and are the practical answer for the outside-sleeping-area location.
Common questions
What does the code say about smoke alarms — in bedrooms for Smoke & CO Alarms?
One in each sleeping room. (IRC R314.3)
What does the code say about smoke alarms — outside bedrooms for Smoke & CO Alarms?
One outside each separate sleeping area, in the immediate vicinity of the bedrooms. (IRC R314.3)
What does the code say about smoke alarms — every story for Smoke & CO Alarms?
At least one per story including basements and habitable attics. (IRC R314.3)
Adopted edition by state
Base-code year from BuildSpec’s adoption records. States often amend the base code, and your city or county may differ, so confirm with your building department.
This guide is BuildSpec’s own summary, not code text. It cites the 2021 International Residential Code and the 2023 National Electrical Code as model standards. The IRC 2021 text itself is in the Code Library for signed-in members; BuildSpec publishes no NEC text, which is at nfpa.org.Neither is an adoption record: your state may be on a different edition with amendments — check your jurisdiction page or get an Address Report.