Home / Code Guides / Smoke & CO Alarms

Smoke & Carbon Monoxide Alarm Placement — Where the Code Puts Them

Smoke alarm placement in a dwelling is a fixed list: each bedroom, outside each sleeping area, and every story. Carbon monoxide alarms attach to the same permit triggers whenever the home has fuel-fired appliances or an attached garage.

RequirementModel Code StandardSection
Smoke alarms — in bedroomsOne in each sleeping roomIRC R314.3
Smoke alarms — outside bedroomsOne outside each separate sleeping area, in the immediate vicinity of the bedroomsIRC R314.3
Smoke alarms — every storyAt least one per story including basements and habitable atticsIRC R314.3
Interconnection & powerHardwired with battery backup and interconnected so all sound together; listed wireless interconnection allowedIRC R314.4, R314.5
CO alarms — whereOutside each separate sleeping area, and required when the dwelling has fuel-fired appliances or an attached garage; in bedrooms when a fuel-fired appliance is in the bedroom or its bathroomIRC R315.2, R315.3
Alterations triggerInterior alterations, repairs, or additions requiring a permit bring the whole dwelling up to smoke/CO alarm requirements (battery-only allowed where no wiring access)IRC R314.2.2, R315.2.2
Kitchen/bath spacingIonization alarms not within 20 ft of a permanent cooking appliance (10 ft with a silencing feature); photoelectric alarms not within 6 ft; not within 3 ft of bath doors with tub/showerIRC R314.3.1

Worth knowing

  • The alterations trigger surprises homeowners: a simple permitted remodel means alarms in every bedroom of a 1970s house.
  • NFPA 72 governs installation details the IRC references — ceiling placement, distance from walls, and sloped-ceiling rules come from there.
  • Many states layer their own CO statutes on top of the IRC, including rental-property requirements.
  • Combination smoke/CO units are permitted and are the practical answer for the outside-sleeping-area location.
Sections cite the 2021 International Residential Code and 2023 National Electrical Code as model standards. This is BuildSpec’s own summary — not ICC or NFPA text; read the authoritative language at codes.iccsafe.org. Your state may be on a different edition with amendments — check your jurisdiction page or get an Address Report.