Residential stairs are governed by four numbers most builders can recite: 7-3/4, 10, 36, and 6-8. Miss the uniformity tolerance, though, and a stair that meets all four still fails.
Worth knowing
- The commercial (IBC) standard is stricter — 7 in. max rise, 11 in. min tread — which is why "code stairs" answers online conflict.
- Spiral stairs have their own allowances: 26 in. clear width, 6-3/4 in. tread at the 12-in. walkline, 9-1/2 in. max rise (R311.7.10.1).
- The 3/8-in. uniformity rule is the most common stair failure — check the first and last riser after flooring changes.
- Winder treads need 10 in. at the 12-in. walkline and 6 in. minimum at any point.
Sections cite the 2021 International Residential Code and 2023 National Electrical Code as model standards. This is BuildSpec’s own summary — not ICC or NFPA text; read the authoritative language at codes.iccsafe.org. Your state may be on a different edition with amendments — check your jurisdiction page or get an Address Report.