Where Tempered (Safety) Glass Is Required — The Hazardous Locations List

The code never says "tempered glass" is required everywhere — it lists hazardous locations where glazing must be safety-rated (tempered or laminated). R308.4 is that list, and most of it is about doors, water, and stairs.

RequirementModel Code StandardSection
In doorsGlazing in all fixed and operable door panels (limited exceptions for small decorative lites)IRC R308.4.1
Adjacent to doorsGlazing within 24 in. of either side of a door and under 60 in. above the floorIRC R308.4.2
Large low windowsPanes over 9 sq ft with bottom edge under 18 in. above floor, top edge over 36 in., and a walking surface within 36 in.IRC R308.4.3
Tubs, showers & poolsGlazing in wet-surface enclosures and within 60 in. horizontally and under 60 in. vertically of the water surfaceIRC R308.4.5
Near stairsGlazing with its bottom edge less than 36 in. above the walking surface of stairways, landings, and ramps; and glazing less than 36 in. above the bottom landing within a 60-in. arc of the bottom treadIRC R308.4.6, R308.4.7
Guards & railingsAll glazing used in guards and railings, including structural baluster panelsIRC R308.4.4
IdentificationEach safety-glazing pane permanently labeled (etched bug) with the standard it meetsIRC R308.1

Worth knowing

  • The classic miss: a fixed window beside a patio door, or a low picture window at a landing — both usually need safety glazing.
  • Protective bars or screens can exempt some locations only under the specific exceptions — not the shower/tub locations.
  • Laminated glass satisfies most hazardous locations where tempered is impractical (e.g., oversized panes).
  • Replacement glazing must meet current safety-glazing rules even in old frames.
Sections cite the 2021 International Residential Code and 2023 National Electrical Code as model standards. This is BuildSpec’s own summary — not ICC or NFPA text; read the authoritative language at codes.iccsafe.org. Your state may be on a different edition with amendments — check your jurisdiction page or get an Address Report.