B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Home / Products / Div 23 81 43 — 23 81 43 / Tempstar Q5H9V48*K*AAA* heat pump (AHRI 217953322)
TempstarDiv 23 · HVACNo manufacturer photo on file
Div 23 81 43 · 23 81 43

Tempstar Q5H9V48*K*AAA* heat pump (AHRI 217953322)

Tempstar · Q5H9V48*K*AAA* [AHRI 217953322]

Tempstar Q5H9V48*K*AAA* heat pump (AHRI 217953322) appears in the U.S. EPA ENERGY STAR "Certified Heat Pumps" dataset, which lists outdoor and indoor unit combinations certified to the program specification (record 4557582, certified 2026-09-16). 1 certified indoor/outdoor combination of outdoor model Q5H9V48*K*AAA* share these rated values. EPA publishes these values: SEER2 (Btu/Wh) 15.50; EER2 (Btu/Wh) 11.00; HSPF2 (Btu/Wh) 9.00; Cooling capacity (Btu/h) 47000; Heating capacity at 47 °F (Btu/h) 46500; Heating capacity at 17 °F (Btu/h) 47000; Heating capacity at 5 °F (Btu/h) 40500; COP at 5 °F 2.10; Product type HP - Split System; Cold climate Yes. The listing records ENERGY STAR certification and the rated values reported to EPA. It is not a determination that any building, installation or design complies with a code.

✓ Verified 2026-10-04
Specs on this page were checked against ENERGY STAR Certified Heat Pumps (data.energystar.gov/d/83eb-xbyy) on 2026-10-04.

Specifications

SeriesQuietComfort 19 SEER2 VS HP
RefrigerantR-454B (GWP:470 | Lower GWP)
COP at 5 °F2.10
Cold climateYes
Product typeHP - Split System
EER2 (Btu/Wh)11.00
HSPF2 (Btu/Wh)9.00
SEER2 (Btu/Wh)15.50
Compressor stagingContinuously variable
Connected capabilityNo
Cooling capacity (Btu/h)47000
Meets most efficient criteriaNo
Meets peak cooling requirementsYes
Heating capacity at 5 °F (Btu/h)40500
Heating capacity at 17 °F (Btu/h)47000
Heating capacity at 47 °F (Btu/h)46500
AHRI reference number (lowest in group)217953322
Certified combinations with these ratings1

Certifications & Standards

ENERGY STAR 4557582 Certified heat pump system, 2026-09-16

Sustainability

No sustainability metrics on file for this product.

Code sections

Sections of the model codes that address this type of product. A link opens the code library at the chapter that holds the section. It points to the code; it does not say this model meets it.

  • IECC 2021 R403.7Equipment sizing and efficiency rating

    IECC 2021 R403.7 governs sizing and the minimum efficiency rating of residential heating and cooling equipment. This is the section for this product type, not a check of this model against it.

    What this link does and does not claim

    Asserted: this is an ENERGY STAR certified heat pump system, and R403.7 is the energy code section that addresses sizing and the minimum efficiency rating of residential heating and cooling equipment. Not asserted: that this model meets any table value in R403.7, or that any building using it complies.

  • IECC 2021 C403.3.2HVAC equipment performance requirements

    IECC 2021 C403.3.2 governs the minimum efficiency of commercial HVAC equipment (Tables C403.3.2(1) through C403.3.2(16)). This is the section for this product type, not a check of this model against it.

    What this link does and does not claim

    Asserted: this is an ENERGY STAR certified heat pump system, and C403.3.2 is the energy code section that addresses the minimum efficiency of commercial HVAC equipment (Tables C403.3.2(1) through C403.3.2(16)). Not asserted: that this model meets any table value in C403.3.2, or that any building using it complies.