B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Home / Products / Div 23 81 43 — 23 81 43 / Willis PUHW12KR32-O heat pump (AHRI 217560052)
WillisDiv 23 · HVACNo manufacturer photo on file
Div 23 81 43 · 23 81 43

Willis PUHW12KR32-O heat pump (AHRI 217560052)

Willis · PUHW12KR32-O [AHRI 217560052]

Willis PUHW12KR32-O heat pump (AHRI 217560052) appears in the U.S. EPA ENERGY STAR "Certified Heat Pumps" dataset, which lists outdoor and indoor unit combinations certified to the program specification (record 4470743, certified 2025-11-07). 1 certified indoor/outdoor combination of outdoor model PUHW12KR32-O share these rated values. EPA publishes these values: SEER2 (Btu/Wh) 21.00; EER2 (Btu/Wh) 13.00; HSPF2 (Btu/Wh) 9.00; Cooling capacity (Btu/h) 12000; Heating capacity at 47 °F (Btu/h) 12000; Heating capacity at 17 °F (Btu/h) 10000; Heating capacity at 5 °F (Btu/h) 10500; COP at 5 °F 1.90; Product type HP - Mini or Multi Split; Cold climate Yes. The listing records ENERGY STAR certification and the rated values reported to EPA. It is not a determination that any building, installation or design complies with a code.

✓ Verified 2026-10-03
Specs on this page were checked against ENERGY STAR Certified Heat Pumps (data.energystar.gov/d/83eb-xbyy) on 2026-10-03.

Specifications

SeriesAll MATCH
RefrigerantR-32 (GWP:675 | Lower GWP)
COP at 5 °F1.90
Cold climateYes
Product typeHP - Mini or Multi Split
EER2 (Btu/Wh)13.00
HSPF2 (Btu/Wh)9.00
SEER2 (Btu/Wh)21.00
Compressor stagingContinuously variable
Connected capabilityNo
Cooling capacity (Btu/h)12000
Meets most efficient criteriaYes
Meets peak cooling requirementsYes
Heating capacity at 5 °F (Btu/h)10500
Heating capacity at 17 °F (Btu/h)10000
Heating capacity at 47 °F (Btu/h)12000
AHRI reference number (lowest in group)217560052
Certified combinations with these ratings1

Certifications & Standards

ENERGY STAR 4470743 Certified heat pump system, 2025-11-07

Sustainability