4161.01GENERAL REQUIREMENTS
Meet the requirements of applicable sections within these specifications for preservative treatment of timber, lumber, piling and posts. Unless specified otherwise, meet the requirements of this section for treatment process and results.
4161.02PRESERVATIVES
Meet the requirements of Section 4160. Unless specified otherwise, treatment may be with any of the preservatives listed. 4161.03 A.
TREATMENT. Except as provided herein, follow the requirements and recommendations of AWPA Standards U1 and T1 and the applicable AWPA Commodity Specifications listed in Tables 4161.03-1 and 4161.03-2 for various materials and usages: Table 4161.03-1: Minimum Preservative Retention Requirements (lb./cu. ft. of wood) Retention
Material and Usage Lumber and Timber for Structures(d)
Creosote(a)
PCP-A(a)
CuN(a)
AWPA U1 AWPA U1 AWPA U1
AWPA ACZA(b) CCA(b,c) MCA(b,c) UC-SectionSpecial Req. AWPA U1
AWPA U1
AWPA U1
AWPA U1
Piles for Foundation, Round Douglas Fir
0.85
0.14
1.0
-
-
Southern Pine
0.60
0.10
0.80
0.80
0.41
UC4C-E
Guardrail Posts, and Spacer Blocks Sawed Four Sides
0.5
0.06
0.4
0.4
0.15
UC4A-A-4.3
0.4
0.15
UC4A-B
Fence, Guide, and Sign Posts Round
0.4
0.055
0.4
Sawed Four 0.5 0.060 0.4 0.4 0.15 UC4A-A-4.3 Sides (a) Oil type preservatives. (b) Waterborne preservatives. (c) Do not use for the treatment of Douglas Fir. (d) Retentions based on AWPA Use Category and Commodity Specifications for different applications.
Preservative Treatment
4161.03
Table 4161.03-2: Minimum Preservative Retention Requirements inches of wood and/or % of sapwood penetration Penetration(1) Material and Usage
Southern Pine
Douglas Fir
AWPA Material Standard Section
Lumber and Timber for Structures(a)
AWPA U1, T1
AWPA U1, T1
AWPA U1, T1
Piles for Foundation:
3.0 in. or 90%
0.75 in. and 85% up to 1.6 in. and 85%
T1-8.5
2.5 in. or 85%
Under 5 in. thick: 0.4 in. and 90% 5 in. and thicker: 0.5 in. and 90%
T1-8.1
2.0 in. or 85%
3/8 in. and 100% up to 1 in. or 85%
T1-8.2
2.5 in. or 85%
Under 5 in. thick: 0.4 in. and 90% 5 in. and thicker: 0.5 in. and 90%
T1-8.1
Guardrail Posts and Spacer Blocks: Sawed Four Sides Fence, Guide, and Sign Posts: Round
Sawed Four Sides (a)
Penetrations based on AWPA Use Category and Commodity Specifications for different applications.
B.
Meet the following requirements for other aspects of the treatment process: 1.
Incising. Incise Coastal Douglas Fir lumber.
2.
Seasoning.
(ACZA, CCA), ensure the moisture content prior to treatment, as determined by resistance type moisture meter, is no more than 20% if kiln dried or no more than 23% if air dried.
penetration up to a maximum of 1.5 inches.
inches or less in nominal thickness and is treated with a waterborne preservative. Dry the lumber to a moisture content of no more than 20% if kiln dried or no more than 23% if air dried.
3.
Special Treatment for Guardrail and Sign Posts Treated With Oil Type Preservative. Before removing sign and guardrail posts from the treatment cylinder, further subject them to live steam at a maximum pressure of 13 psi. Following that, subject the posts to an additional period of vacuum to ensure that the surface of the wood is free from accumulation of oil type preservative.
4161.03
Preservative Treatment
4.
Method of Treatment.
contract item or order.
air pressure for creosote, pentachlorophenol, or copper naphthenate treatments.
5.
Results of Treatment.
Tables 4161.03-1 and 4161.03-2, unless specified otherwise.
Standards U1 and T1 and the applicable AWPA Specifications listed in Tables 4161.03-1 and 4161.03-2.
6.
Handling Treated Products. Follow AWPA Standard M4 regarding care and handling of preservative treated wood products. End cuts, drilled holes, other fabrication after treatment, and damage/injuries require field treatment and shall be treated with preservatives as specified in AWPA M4.
7.
Product Marking.
legible identification mark that is either hammer or heat branded, die stamped, or metal tagged. For material treated with waterborne preservatives, the identification mark may be ink stamped provided the information is clearly visible and legible. Ensure the identification mark, as a minimum, indicates the treater, the species of wood, the preservative treatment type, and the retention level. Acceptable brands or marks are to be similar to the general guidelines for brands listed in AWPA M1 and M6.
exception of 45 inch Terminal Posts1, displays a quality grade mark of an accredited grade monitoring and inspection agency approved under the American Lumber Standards Committee (ALSC). 1 In the event that Terminal Posts 45 inches in length to be used for Guardrails cannot be stamped with a quality grade mark due to sizing of material, ensure Terminal Posts are instead stamped "MFG No. 1" to indicate that the Terminal Posts were cut from an original piece graded as a No. 1. Wane requirements will be waived.
however, ensure a statement from the mill/processor certifying the grade of the material is provided. See Documentation Section of Materials I.M. 462. Round wood posts, round wood piles, and round wood poles do not require a grade, since the grading rules apply only to sawn material.
plastic tag identifying the charge number for the bundle.
Untreated Timber and Lumber
8.
4162.03
Inspection. Furnish white and treatment inspections, certifications, and test reports for each shipment according to Materials I.M. 462.