861DIGITAL TIME SWITCH

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 741–741 Save this section

Ask about Section 861

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Art. 861.01 Digital Time Switch SECTION 861. DIGITAL TIME SWITCH

861.01 Description. This work shall consist of furnishing, installing, and

setting a digital time switch, with necessary connections for proper operation.

861.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Digital Time Switch ............................................................................ 1074.01

861.03 Basis of Payment. This work will be paid for at the contract unit price

per each for DIGITAL TIME SWITCH. SECTION 862. UNINTERRUPTABLE POWER SUPPLY (UPS)

862.01 Description. This work shall consist of furnishing and installing an

uninterruptable power supply (UPS).

862.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Uninterruptable Power Supply ........................................................... 1074.04 CONSTRUCTION REQUIREMENTS

862.03 General. The UPS shall provide power for full run-time operation for

an “LED-only” intersection (all colors red, yellow, and green) or flashing mode operation for an intersection using red LED’s. A UPS that provides a minimum of two hours of full run-time operation will be designated as “standard”. A UPS that provides a minimum of six hours of full run-time operation will be designated as “extended”. The UPS shall include, but not be limited to the following: inverter/charger, power transfer relay, batteries, a separate manually operated non-electronic bypass switch, and all necessary hardware and interconnect wiring according to the plans. The UPS shall provide reliable emergency power to the traffic signals in the event of a power failure or interruption. The transfer from utility power to battery power and visa versa shall not interfere with the normal operation of traffic controller, conflict monitor/malfunction management unit, or any other peripheral devices within the traffic controller assembly. The UPS shall be designed for outdoor applications, and shall meet the environmental requirements of, “NEMA Standards Publication No. TS 2 – Traffic Controller Assemblies”, except as modified herein.

862.04 Basis of Payment. This work will be paid for at the contract unit price

per each for UNINTERRUPTABLE POWER SUPPLY, STANDARD or UNINTERRUPTABLE POWER SUPPLY, EXTENDED.

Get an email when 861 changes

Illinois revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Illinois Standard Specifications for Road and Bridge Construction, 2022 Edition. Pages 741–741 of 1,217. View official source ↗