882TRAFFIC SIGNAL BACKPLATE

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 757–757 Save this section

Ask about Section 882

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Art. 882.04 Directional Louver

882.04 Basis of Payment. This work will be paid for at the contract unit price

per each for TRAFFIC SIGNAL BACKPLATE, of the type specified, and of the particular kind of material, when specified. SECTION 883. DIRECTIONAL LOUVER

883.01 Description. This work shall consist of furnishing and installing a

directional louver for a 12 in. (300 mm) signal lens in the signal heads.

883.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Directional Louver .............................................................................. 1078.04 CONSTRUCTION REQUIREMENTS

883.03 Installation. The directional louver shall provide an angle of cutoff on

each side of the center axis of the light beam as follows. Type A 0 to 6 degrees Type B 7 to 10 degrees Type C 11 to 14 degrees The directional louver shall be installed inside the signal visor in front of the signal lens and secured in place with a minimum of two metal screws.

883.04 Basis of Payment. This work will be paid for at the contract unit price

per each for DIRECTIONAL LOUVER, of the type specified. When used with a 8 in. (200 mm) lens, this work will be paid for at the contract unit price per each for DIRECTIONAL LOUVER, of the type specified. DETECTION SECTION 885. INDUCTIVE LOOP DETECTOR

885.01 Description. This work shall consist of furnishing and installing an

inductive loop detector.

885.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Inductive Loop Detector ..................................................................... 1079.01 CONSTRUCTION REQUIREMENTS