2401 - WATER FOR USE WITH CEMENT 2400-1
2401.1 Description
This specification covers water for use with cement.
2401.2 Requirements
a. Source. Use only water from sources approved by the Engineer for cement. Approval of a water source may be withdrawn during construction if changes in quality occur. b. Purity.
2401.3 Test Methods
TABLE 2401-1: REQUIRED TEST METHODS Requirement Test Method Specific Conductance ASTM D 1125 Sodium Chloride ASTM D 512 Sodium Sulfate ASTM D 516 Total Solids Standard Methods for Examination of Water and Wastewater, American Public Health Association, Inc. Time of Set (Gillmore) ASTM C 266 Mortar Strength ASTM C 109
2401.4 Prequalification
None Required.
2401.5 Basis of Acceptance
a. Acceptance of all water for prestressed concrete will be based on the results of tests conducted at MRC. b. Water for use with cement in other applications will be accepted for use if it is obtained from a city water supply that is approved for domestic use by the Kansas Department of Health and Environment (KDHE). Water from other sources will be tested before acceptance for use.