– CONCRETE FOR PRESTR ESSED CONCRETE MEMBERS CONCRETE FOR PRESTRESSED CONCRETE MEMBERS
404.1DESCRIPTION
Provide concrete with the release and 28 day compre ssive strengths specified in the Contract Documents. This specification is specific to Concrete for Prestressed Concrete Members. See SECTION 401 for general concrete requirements.
404.2MATERIALS
Provide materials that comply w ith the applicable requirements. General Concrete .................................................................................................... … SECTION 401 Aggregate ............................................................................................................... ….. DIVISION 1100 Admixtures and Plasticizers .................................................................................. ….. DIVISION 1400 Grade 2 Calcium Chloride ...................................................................................... ….. DIVISION 1700 Cement, Fly Ash, Silica Fume, Slag Cement and Blended Supplemental Cementitious........................................................................................................... …. DIVISION 2000 Water ………………………………………………………………. ..................... ….. DIVISION 2400
404.3CONCRETE MIX DESIGN
by the Engineer before the mix can be used in the production of prestressed concrete members.
outlined in SECTION 401, or use TABLE 404-2 to design structural concrete mixes.
concrete to meet the compressive strength requirements of TABLE 404-1 . For prestressed bridge beams, the Engineer will determine the strength requirements from the table except when specified elsewhere in the Contract Documents. TABLE 404-1: COMPRESSIVE STRENGTH REQUIREMENTS Type of Unit For Stress Application
Age 28 Days (Minimum)** (psi) Prestressed Bridge Beams 5800 7000 4800 6000 4000 5000 Prestressed Piles 3000 5000 Prestressed Panels 4000 5000 * From casting bed to producer’s storage only. Not a shipping strength. ** Also required for shipping strength.
Cementitious Materials. Unless specified otherwise in the Contract Documents, select the type of portland cement, blended hydraulic cement and indi vidual and blended supplemental cementitious materials according to SECTION 401. – CONCRETE FOR PRESTR ESSED CONCRETE MEMBERS
meet the requirements of TABLE 404-2. TABLE 404-2: CONCRETE REQUIREMENTS Self-Consolidating Concrete (SCC) Non SCC All Concrete Slump Flow From Target (Inches) Blocking Assessment (Inches) Visual Stability Index Maximum Slump (Inches) Minimum Cementitious per Cubic Yard (Lbs) Mixing Water: Maximum lb. per lb. Cementitious Air Content (%) ± 2 2 maximum 0 or 1 5 or 7 ± 25% 602 0.44 6.5 ± 1.5
Consolidating Concrete.” The target value is determined during the mix design and approval process (see below). At the point of placement, slump flow can deviate from target by no more than 2 inches.
Self-Consolidating Concrete by J-Ring.”
the Engineer, the VSI may be determined using additional concrete stability observations.
range or high-range water reducing admixtures. When a water reducing admixture is being used, designate a slump no greater than 7 inches. The tolerance from design at the point of delivery is ± 25%.
that complies with placement, and the release and 28-day strength requirements.
excludes water of absorption of the aggregates.
wetting and drying.
Method) meter may be used for production with random verification by the Volumetric Method. See KT-19 for special requirements when using the Volumetric Method with high cemen titious concretes or mixtures with midrange water reducers or plasticizers.
Concrete Not Placed on Grade. Keep a copy of the KDOT O fficial Quality test report from the approved source on file at the prestress plant and available for review by the Engineer.
Placed on Grade.
fume cannot be added to the cementitious materials, add th e loose silica fume to the bo ttom of the stationary drum that is wet, but has no standing water, before adding the dry materials. The Engineer may approve shreddable bags on a performance basis, only when a central batch mixing process is used. If so, add the bags to half of the mixing water and mix before adding cementitious materials, aggregate and remainder of water. The presence of visible chunks or wads of bag paper at the point of placement will be cause for rejection. Mix silica fume modified concrete for a minimum of 100 mixing revolutions, unless high speed mixing equipment is used.
subsection 401.3d.(6) for requirements. ASTM C 1567 is not necessary for concrete modified with only Silica Fume.
available for review by the Engineer.
plant and available for review by the Engineer. No other additives may be used without written approval by the Engineer. – CONCRETE FOR PRESTR ESSED CONCRETE MEMBERS
mixture which can be placed by means of its own weight with little to no vibration. It is accomplished by adjusting traditional mix designs using special admixtures.
traceable) and approved by the Engineer.
prestressed beams. Any change in admixture, aggregate source or gradation, cementitious material content or source, and strand producer or size requires that a new strand bond test be completed using the replacement materials. Make 2 test beams for each bond test. Cure the test beams in an environment that is representative of future production (i.e. – moisture and heat until release then ambient conditions).
This spread establishes a target value from whic h future point of placement values are to be compared to. Assign a Visual Stability Index (VSI) number to the concrete spread.
Calculate a “blocking assessment” value.
the test beams they represent.
release (equal to the release strength of future production). De-tension the strand in both test beams only after this cylinder set indicates that release strength has been attained.
28-day strength (equal to the 28-day strength of future production). Perform the bond test on both test beams only after this cylinder set indicates that the 28-day strength has been attained.
cylinders equals or exceeds the required strength, and no more than 1 cylinder in the tested set had a strength that was no more than 5% below the required strength.
casting tolerances. Calculate the weight of the required test loads.
observations, measurements, pictures, and test results related to strand bond, cylinder strength, slump flow, and J-ring testing to the Engineer for review.
this testing may be approved provided there are 2 passing bond tests, and the assigned blocking assessment and the calculated VSI satisfy the requirements of TABLE 404-2.