803 - FIELD OFFICE AND LABORATORY 800-8
803.1 Description
Provide the designated types of field offices and laboratories shown in the Contract Documents. B I D I T E M S U N I T S F i e l d O f f i c e E a c h Field Office and Laboratory (*) Each *Type: A, B or C
803.2 Materials
Provide a field office and laboratory that complies with TABLE 803-1. TABLE 803-1: REQUIREMENTS FOR FIELD OFFICE AND LABORATORY Requirements Type A Type B Type C Field Office Minimum floor area (square feet). 230 160 120 160 Minimum inside width (feet). 9 7 7 7 Minimum ceiling height (feet). 7 7 7 7 Minimum number of windows with screens. Sliding or swinging windows (minimum area per window of 4 square feet) on a minimum of 2 sides of the building. 6 4 4 4 Minimum number of locking outside doors with screen doors. 2 1 1 1 Partitioned for a laboratory area and a drying room. 70 square feet minimum floor area for the drying room. Approximate length of workbench for the drying room of 7 feet. The drying room must have a minimum of 1 window and 1 outside door. yes no no no Insulated and weather tight. yes yes yes yes Electrical supply 110 volt AC. Install devices necessary to provide transient voltage surge suppression at the building main circuit breaker panel. yes yes no yes Minimum number of electrical outlets. Space outlets uniformly throughout the building. 6 6 n/a 6 Minimum number of light fixt ures. Uniformly space light fixtures to light the interior of the building. 3 2 n/a 2 Water supply. Provide a minimum pressure of 5 psi, or a minimum head of 12 feet, if a gravity tank is used. yes yes yes** no Sink and faucet. Minimum sink dimensions: 30 inches long, 24 inches wide and 6 inches deep. The faucet must have a hose connection. yes yes yes** no Minimum total length of workbench (feet). Minimum workbench dimensions: 30 inches wide and 36 to 42 inches high. 30 20 10 20 Number of chairs or stools for use at the workbenches. 2 2 2 2 Writing table or desk with chair. Approximate size of writing table or desk: 5 feet by 30 inches and 30 inches high. yes yes yes yes Heating system capable of maintaining a minimum temperature of 70°F. yes yes yes yes 803 - FIELD OFFICE AND LABORATORY 800-9 TABLE 803-1 (cont.) Requirements Type A Type B Type C Field Office Air-conditioning system capable of maintaining a temperature below 85°F. yes no no yes Provide a private telephone line service protected from surge voltages. Also, provide Broadband internet connection (for a minimum of 4 computers) to the Field Office and Laboratory (Type A) designated by the Engineer as the primary field office. yes no no yes Exhaust fan. yes* yes* no no Ovens for drying samples. Provide gas or electric as necessary for the ovens. yes no*** no*** no Fire extinguisher yes yes yes yes *Type A: Provide an exhaust fan in the drying room capable of changing the air in the room every minute. Type B: the exhaust fan shall be capable of changing the air in the building every 3 minutes. ** Only when required for testing. ***Provide gas for drying samples, when required. The Engineer will accept the field offices and laboratories based on compliance with the specified requirements and visual inspection for condition. The DME may accept a non- compliant field office and laboratory if it will meet the needs of the project.
803.3 Construction Requirements
When ordered by the Engineer, provide the designated field offices and laboratories for the exclusive use of the Engineer. Set up the field offices and laboratories at the locations designated by the Engineer. Secure and support the field offices and laboratories to prevent vibrati ons. If the Engineer determines it is necessary to relocate the field offices and laboratories during the progress of the project, relocate th e field offices and laboratories to the locations designated by the Engineer. Remove the field offices and laboratories when released by the Engineer. If the Engineer determines that additional field offi ces and laboratories (of the types designated in the Contract Documents) are required, provide the types and number of field offices and laboratories requested. On KDOT-tied projects, where the bid items for field offices and laboratories are shown only on one project, provide the field offices and laboratories for use on all of the related KDOT-tied projects. On KDOT-tied projects, where the bid items for field offices and laboratories are shown on more than one project, the Engineer may determine separate labs are not need ed for each project. If the same lab is used for all the projects, it will only be paid for on the project with the largest original contract dollar amount, and the bid item will be underrun from the other projects.
803.4 Measurement and Payment
If the Engineer informs the Contractor at the pre-cons truction conference that the field office or field office and laboratory are not required, the Engineer will underrun this item. The Engineer will measure each field office and field office and laboratory. The Engineer will measure each unit on each project only once, even if the unit is relocated. On KDOT-tied projects, the Engineer will measure each unit only once on one of the KDOT-tied projects, even when the unit is used on all related KDOT-tied projects. If the unit is shown on more than one project, it will only be measured and paid for on the project with the largest original contract dollar amount, and the bid item underrun from the other projects. A Field Office and Laboratory (Type A) may be subs tituted for and measured for payment as a Field Office and Laboratory (Type B), a Field Office and Laboratory (Type C) or a Field Office. A Field Office and Laboratory (Type B) may be substituted for and measured for payment as a Field Office and Laboratory (Type C). Payment for "Field Office and Laboratory" and "Fie ld Office" at the contr act unit prices is full compensation for the specified work. Th e contract unit prices for the various types of field offices and laboratories will govern, regardless of the number of units used on the project. The Engineer will make partial payments according to TABLE 803-2. 803 - FIELD OFFICE AND LABORATORY 800-10 TABLE 803-2: FIELD OFFICE AND LABORATORY PARTIAL PAYMENTS Condition Pay % of Contract Unit Price 1st estimate after the unit is provided & accepted 40 3 months after accepted 70 When released by Engineer 100 If the Engineer determines that telephone service is unnecessary for "Field Office and Laboratory (Type A)" and "Field Office", the Engineer will reduce the contract unit price for these items by 10%. If the Engineer determines that broadband internet service is not available for "Field Office and Laboratory (Type A)", provide a fax machine, at no additional cost. If the Engineer determines that broadband internet service is unnecessary for "Field Office and Laboratory (Type A)", the Engineer will reduce the contract unit price for this item by 10%. If the Engineer requests that the field office and labora tory be relocated, the Engineer will pay a relocation fee of $300 per relocation for "Field Office and Laboratory (Type A)" and "Field Office and Laboratory (Type B)" bid items, and $150 per relocation for "Field Office and Laboratory (Type C)" and "Field Office". The relocation fees will be paid for at the amounts shown, as Extra Work, SECTION 104.
Field office and Laboratory in other states