B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Category 400 — Structures

470Utilities on Structures

MD · 2026 Standard Specifications✓ Full text on BuildSpecBook pages 598–599 Save this section

Ask about Section 470

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

470 — UTILITIES ON STRUCTURES 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS CATEGORY 400 STRUCTURES SECTION 470 — UTILITIES ON STRUCTURES

470.01 Description

Place utility markers to identify utilities when they are newly installed, replaced, or relocated. Place the identification markers as specified herein and as approved.

470.02 Materials

Utility Facility Identification.

a.Any new or replacement utility facility installed shall include an identification marker with the first 50 ft of the facility, the last 50 ft of the facility, and at intervals of 100 ft in-between.
1.Adjust the spacing to have one marker in every bay bounded by beams and diaphragms through which the utility passes.
b.The marker shall consist of decals or stenciling onto the pipe or carrier according to industry standard color coding with high quality black or white print.
1.Provide lettering height of 1/3 the pipe diameter, but not smaller than 1 in. nor larger than 4 in.
2.The markers shall include the name of the utility and a description of the contents including pressure, voltage, and any other pertinent information required by industry standards. LABEL BACKGROUND COLOR / LETTERING COLOR CONTENT RED Electrical Power YELLOW Gas, Oil Steam, Petroleum or Gaseous Materials ORANGE Communication, CATV, Alarm, or Signal BLUE Potable Water PURPLE Reclaimed Water, Irrigation, or Slurry GREEN Sewer and Storm Drain Figure 470.02(b) – Industry Standard Color Coding 470 — UTILITIES ON STRUCTURES 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS

470.03 Construction

Place identification markers within the first and last 50 ft of the structure, and at intervals not to exceed 100 ft. Ensure that the surface to receive the marker is properly cleaned and prepared prior to the application. Orient the markings for best visibility.

470.04 Measurement and Payment

The application of utility markers on structures will not be measured but the cost will be incidental to the pertinent items.

Sections that cite this one

Get an email when 470 changes

Maryland revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Standard Specifications for Construction and Materials, 2026 Edition. Pages 598–599 of 1,138. View official source ↗

Ask about this section

Scoped to Maryland Standard Specifications for Construction and Materials, Section 470 — Utilities on Structures. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.