925 — DETECTABLE WARNING SURFACE 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS CATEGORY 900 MATERIALS SECTION 925 — DETECTABLE WARNING SURFACE

925.01 General

Detectable warning surfaces shall conform to the current accessibility guidelines of the Americans with Disabilities Act (ADA). The Office of Materials Technology (OMT) maintains a Qualified Products List (QPL). Manufacturers seeking inclusion of their product on the QPL shall submit certified test results showing conformance to the properties in 925.07, as well as installation instructions and the types of adhesives and sealants required.

925.02 Composition

Warning surfaces shall be either flexible or rigid. If there is a change in the composition of a qualified product, the manufacturer shall notify OMT and submit new test results showing conformance with 925.07.

925.02.01 Pavers. Type III Brick Pavers shall conform to the requirements of C 902, Class SX,

Type 1, and Application PX. The pavers shall be 2-1/4 in. x 4 in. x 8 in. with square edges and a surface meeting 925.03.

925.03 Configuration and Dimensions

The warning surface shall consist of a system of truncated domes having a base diameter of 0.9 in. to 1.4 in., a top diameter 50 percent to 65 percent of the base diameter, and a height of 0.2 in. The domes shall be arranged in a square grid with center to center spacing of 1.60 in. to 2.40 in.

925.04 Color

The color shall be homogeneous across the surface of the material and contrast with adjoining surfaces.

925.05 Identification

The top surface shall have an identifier that uniquely distinguishes the manufacturer. Brick pavers are excluded. 925 — DETECTABLE WARNING SURFACE 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS

925.06 Requirements

TYPE DESCRIPTION PHYSICAL TEST REQUIREMENTS Type I Cast in Place A, B, C, D, E, G Type IIa Surface Mount, Rigid A, B, C, D, E, G Type IIb Surface Mount, Flexible A, B, C, D, F, G Type III Brick Pavers 925.02.01 Type IV Prefilled Pavers A, B, C, D, G

925.07 Physical Properties

PROPERTY TEST METHOD SPECIFICATION LIMIT A Slip Resistance Coefficient C1028 (dry method) 0.80 min B Abrasive Wear, index C501 150 min C Fade (UV) Resistance/Color Retention D4587 Fade or Change in color after 2000 hrs less than ΔE =5* D Freeze/Thaw Resistance C1026 No disintegration E Adhesion/Bond Strength, pull off C482/C 882(as appropriate) No adhesion failure F Adhesion/Bond Strength, peel D903/D429 (modified as appropriate) No adhesion failure G Contrast Contrast percentage formula** using E1349 to determine cap Y brightness/light reflectance values (LRV) Current ADA requirement*** *Chromaticity coordinates (L*a*b* system) checked in conformance with D2244, before and after test. **Contrast % = [(B1 – B2)/B1] x 100, where B1 = (LRV) of the lighter area, and B2 = (LRV) of the darker area ***For the purpose of determining whether a material meets acceptable contrast criteria, use actual cap Y brightness of detectable warning surface, and assume a value of 15 for the cap Y brightness of cured concrete, or a value of 3 for asphalt wearing surfaces to determine percentage difference. Detectable warning surfaces to be installed on other materials are required to undergo additional testing.

Sections that cite this one

Get an email when 925 changes

Maryland revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Standard Specifications for Construction and Materials, 2026 Edition. Pages 1084–1085 of 1,138. View official source ↗

Ask about this section

Scoped to Maryland Standard Specifications for Construction and Materials, Section 925 — Detectable Warning Surface. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.