666.04 682 Cut off all stubs or improper cuts resulting from former pruning or limbs that have been broken flush with the trunk or limb of the tree in order to ensure proper healing.
666.04 Painting. Paint all cuts or wounds measuring 1 inch (25 mm) or more
in diameter and all exposed wood and scars resulting from previous work or damage with approved tree wound dressing.
666.05 Removal o f Foreign Materials from Trees. Remove all nails, spikes,
bolts, wire, or other foreign materials driven into or fastened to the trunk or branches of the tree, or, if directed by the Engineer, cut them flush with the bark of cambium layer to ensure complete healing over.
666.06 Removal of Rubbish. Legally use, burn, or dispose of all material
according to 105.16 and 105.17.
666.07 Method of Measurement. The Department will measure Pruning
Existing Trees by the number of each size, completed and accepted.
666.08 Basis of Payment. The Department will pay for accepted quantities at
the contract prices as follows: Item Unit Description 666 Each Pruning Existing Trees, 3 to 8 -inch (80 to 200 mm) Diameter 666 Each Pruning Existing Trees, 8 to 16 -inch (200 to 400 mm) Diameter 666 Each Pruning Existing Trees, 16 to 24 -inch (400 to 600 mm) Diameter 666 Each Pruning Existing Trees, 24 to 36 -inch (600 to 900 mm) Diameter 666 Each Pruning Existing Trees, 36 inches (900 mm) and Over ITEM 670 EROSION PR OTECTION
670.01 Description
670.02 Materials
670.03 Construction
670.04 Maintenance
670.05 Method of Me asurement
670.06 Basis of Payment
670.01 Description. This work consists of furnishing, placing, and maintaining
slope, ditch, and vegetated swale erosion protection as shown on the plans.
670.02 Materials. Furnish materials conforming to:
Sodding ................................ ................................ .. 660.0 2 Erosion Control Mats ................................ ............. 712.11 670.03 683 For slope erosion protection, the Contractor may use any of the above materials. For ditch erosion protection, use only Item 660 Sodding or Item 671 Erosion Control Mat Type B, C, E, or G or as specified in the plans. For v egetated swale erosion protection, use only Item 671 Erosion Control Mat Type B or as specified in the plans.
670.03 Construction. Install sodding according to Item 660. Install erosion
control mats according to Item 671.
670.04 Maintenance. Maintain so dded areas as specified in Item 660. Maintain
erosion control mats as specified in Item 671.
670.05 Method of Measurement. The Department will measure Slope Erosion
Protection, Ditch Erosion Protection, and Vegetated Swale Erosion Protection by the numbe r of square yards (square meters) completed and accepted. The Department will determine the area based on the surface area covered by the slope, ditch, or swale erosion protection.
670.06 Basis of Payment . The Department will pay for surface preparation,
topsoil, lime, fertilizer, seeding and mulching of areas covered by the mats/sodding under Item 659. The Department will pay for accepted quantities at the contract prices as follows: Item Unit Description 670 Square Yard Slope Erosion Protection (Squa re Meter) 670 Square Yard Ditch Erosion Protection (Square Meter) 670 Square Yard Slope Erosion Protection Mat Type __ (Square Meter) 670 Square Yard Ditch Erosion Protection Mat Type __ (Square Meter) ITEM 671 EROSION CO NTROL MATS
671.01 Description
671.02 Materials
671.03 Construction
671.04 Maintenance
671.05 Method of Measurement
671.06 Basis of Payment
671.01 Description. This work consists of furnishing, placing, and maintaining
Types A through I erosion control mats. This work als o consists of furnishing, placing, and maintaining seeding and mulching when the seeding and mulching is to be held in place with erosion control mats.
671.02 Materials. Furnish materials conforming to:
Seed and Mulch ................................ ........................... 659 Lime and Fertilizer ................................ ...................... 659 671.03 684 Erosion C ontrol Mats ................................ ............. 712.11 If the mat type is not specifically itemized, furnish any mat type listed in 712.11. Furnish staples consisting of 12 inch (0.3 m) No. 11 gage steel wire bent into narrow U -shape with the ends of the staples approximately 1 inch (25 mm ) apart producing a 6 inch staple or furnish pins conforming 18 inch (450 mm) long, 1/4 inch (4.5 mm) in diameter, with attached 1 1/2 inch (38 mm) washer. Drive staples until the staple is flush with the ground surface. Drive pins until the attached wash er is flush with the ground surface. For clay, shale, and other heavy soils, furnish 3 inch (75 mm) steel staples, No. 9 gage or thicker with points approximately 1 inch (25 mm) apart, as required by the Engineer.
671.03 Construction. Before placing any type of temporary erosion control
mats, prepare the surface, apply the fertilizer and lime if specified, and seed as specified in Item 659 or as shown on the plans. Place the temporary erosion control mat in the locations shown on the plans.
671.04 Maintenance. Maintain the specified areas until all work in the Contract
has been completed and the Engineer issues the final acceptance. Re store damaged areas to the condition and grade existing just before placing the mat. Relime, refertilize, and reseed restored areas according to 659. Replace all damaged mats.
671.05 Method of Measurement. The Department will measure Erosion
Contro l Mat, Type ___ by the number of square yards (square meters) completed and accepted. The Department will determine the area based on the surface area covered by the erosion control mat.
671.06 Basis of Payment. The Department will not pay for maintenanc e as
detailed in 671.04 that is required due to the Contractor’s negligence, carelessness, or failure to install erosion controls. If erosion control items in the Contract are properly placed according to the Contract Documents, the Department will pay for maintenance detailed in 671.04 or according to 109.05. The Department will pay for liming and fertilizing of areas covered by the mats under 659. The Department will not pay for the seeding and mulching performed under or over the mats. The Departme nt will pay for accepted quantities at the contract prices as follows: 671.06 686 Item Unit Description 671 Square Yard Erosion Control Mat, Type ___ (Square Meter) 671 Square Yard Erosion Control Mat (Square Meter) 700.00 700 MATERIAL DETAILS 700 MINIMUM REQUIREMENTS FOR SAMPLING MATERIALS Spec No. Material Material only Inspection or Sampling Requirements Additional Instructions Embankment Assure 203.02 Q and R materials conform to the individual material requirements. Sample materials when requested by the Engineer. Follow S 1015 for acceptance . Soil Embankment: 50 lb (23 kg) Granular Embankment: 50 lb (23 kg)
258.02 Load Transfer
Retrofit Silicone Sealant – Obtain letter of certification stating that the material meets the requirements of Item 258. Material to be shipped from manufacturer not more than 9 months prior to use. Patching material - Verify brand name of material is on QPL at the time of use. Notify District Testing if rejecting material. If material non -performs or looks defective during use submit a 1 quart sample to OMM. 304 Aggregate Base Perform compaction conforming to S 1015 and 304.05 Products will be supplied by a S1069 Pre- Qualified Producer/Supplier. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use submit two 60 lb bag samples to OMM for testing. PC Concrete Pavement Base Make two 6"x6"x4' beams for every 7500 yd² (6500 m²) or fraction thereof daily. Field test beams for required load for the specification. Report results in SM. Core samples taken every 2000 sq. yds by Contractor. Conform to S 1064 . 407 Tack Coat If obtaining a sample , draw a t least 1 gallon from the sampling valve or tap and discard prior to obtaining a 1 quart sample. Tag and ship sample to the District lab for OMM Asphalt section testing. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use submit a 1 quart sample to OMM . 409 Sawing and Sealing Asphalt Concrete Pavement Joints Inspect material for condition. Document in SM. Follow joint seal material sections for sampling and acceptance requirements . Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM . 451, 452 PC Concrete Pavement Make 6"x6"x4' beams for every 7500 yd² (6500 m²) or fraction thereof daily. Make two beams if testing before 7 days. Field test beams for required load for the specification. Report results in SM. Core samples taken every 2000 yd by Contractor. Conform to S 1064 .
451.09 B Dowel Bond
Breaking Material Check new light form oil by labels on new cans. No sampling required 499 Various Concrete Items A sample for concrete strength testing consists of a set of three 4 × 8 inch cylinders when the maximum nominal aggregate is 1 inch or less. For concrete wi th maximum nominal aggregate sizes greater than 1 inch, a sample consists of a set of two 6 × 12 inch cylinders. Within 24 to 48 hours after sampling, ship cylinders to District Testing with required documentation.
499.02 Water
Potable water is satisfactory. If question about water quality, obtain 1 gallon sample. Document in SM. Notify District Testing if water appears to contain sewage, oil, acid, or other matter. 503.08 Excavation for Structures - Backfill Material Sample only when requested by the Engineer per Item 203. Soil Embankment: 50 lb (23 kg) Granular Embankment: 50 lb (23 kg)
507.09 Bearing Piles
Steel Pile Points Only use points from suppliers on the Approved List on the Office of Materials Management website. Document bearing piles in SM. Notify District Testing if material non-performs or looks defective during use. Notify the contractor with non -compliance issues. 700.00 688 509.08 Reinforcing Steel - Plastic support chairs Assure plastic supports conform to 709.15. Maximum spacing of supports in slabs, beams and girders to be 4 feet or less to prevent substantial deflection. 511 Concrete for Structures NON QC/QA SPECIFICATIONS Make one set of cylinders for spans over 20 ft each day, each 200 yd³. For span s 20 ft span and under, make one set of cylinders each 50 yd³ or less. Document in SM . Field or Standard Cure according to ACI/ODOT specifications. QC/QA SPECIFICATIONS Follow requirements of 455 for quality assurance sampling and testing. Document in SM. Within 24 to 48 hours after sampling, ship cylinders to District Testing with required documentation. Within 24 to 48 hours after sampling, ship quality assurance cylinders to District Testing with required documentation. 515 Prestressed Concret e Bridge Members Assure products are supplied by a source on the Certified List for S 1079 maintained by OMM. Receive with TE -24. Check dimension and condition Document in SM. If rejecting material because material non -performs or looks defective during use, notify District Testing and OMM .
515.15 Prestressed Concrete
Bridge Members - Corrosion Inhibitors Verify company and brand name of material is on QPL at the time of use. Document in SM. For precast beams delivered on TE-24, verification performed b y OMM. 526 Approach Slabs Make one set of cylinders for each day, each 200 yd³. Document in SM. Field or Standard Cure according to ACI/ODOT specifications. QC/QA SPECIFICATIONS Follow requirements of 455 for quality assurance sampling and testing. Document in SM. Within 24 to 48 hours after sampling, ship cylinders to District Testing with required documentation.
609.02 Curbing, Concrete
Medians, and Traffic Islands - Stone Curbs Contact District Testing and OMM to assure stone curb conforms to req uirements of
609.02 .
Cellular Retaining Walls 610.04.A Cellular Products will be supplied by a source on the Certified Lists for S 1073 maintained by OMM. Receive with TE -24. Check dimension, condition and compliance with approved drawings.
610.04 B Cellular Products accept by certified
test data documentation at the Project. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 613 Low Strengt h Mortar Backfill Supplier to perform trial batches of 1 cy to ensure flowable consistency and yield. Refer to Item 613.05 for alternate mix design. Submit Alternate mix designs for approval 30 days prior to placement... When using foundry sand, obtain writ ten permission from EPA ten days before use. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 632.11 Loop Detector Sealant Verify manufacturer is on QPL. Inspect for condition, appearance and package markings. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 653.02 Topsoil Obtain one (1) pint sample of material fro m each source and/or stockpile of visually different material from same source. Use friction top, air tight metal container supplied by the Department. Submit to Office of Geotechnical Engineering Operations. Samples will include a TE -31 form or SM print screen . 700.00 689 657.02 RipRap for Tree Protection Confirm with OMM that the aggregate source has a n acceptable performance history. Sources with poor performance require test data conforming to ASTM D5240 .
658.02 Tree Root Aeration -
Aggregate Assure source is on the Certified Li st for S 1069 maintained by OMM. Assure aggregate meets soundness requirements. For sources with no soundness history , obtain a 100 lb (45 kg) sample .
659.03 Liming Materials Only accept materials from suppliers licensed
in Ohio. See OMM website for list of Ohio Department of Agriculture list of licensed suppliers. Document in SM.
659.04 Commercial
Fertilizer Only accept materials from suppliers licensed in Ohio. Se e OMM website for list of Ohio Department of Agriculture list of licensed suppliers. Inspect material for certified analysis and condition. Non-standard application rate require s approval prior to use . Document in SM . Licensing is required. Notify Distr ict Testing if rejecting material. If material non -performs or looks defective during use notify District Testing & OMM. 659.07 659.08 659.09 S1022 Seeds Legumes Native Grasses and Wildflowers Verify manufacturer is on Certified Supplier List maintained by OMM. Receive with TE -24 and description bill of lading. Document in SM . Verify District approval of seed mixture. 659.14 659.15
659.16 Mulch Material should be reasonably free from
foreign matter that would inhibit seed germination. Notify District Testing if rejecting material.
660.02 Sodding Materials Verify company and brand name of material is
on QPL at the time of use. Certification required for each shipment. Document in SM . Notify District Testing if rejecting material. 661 Planting Trees Shrubs , Perennials and Vines Verify company and brand name of material is on QPL at the time of use. Inspect material for condition. Plant material should be sealed until use d. Document in SM . Final acceptance should take place after period of establishment. Notify District Testing if rejecting material. STANDARD MATERIALS SPECIFICATIONS 701.01 701.02 701.04 701.05 701.07
701.09 Cement, Hydraulic
ASTM Types I, IA, II, III Masonry Type IS(<25) Verify manufacturer on Concrete Plant Batch Ticket is on Certified List for S 1028 maintained by OMM. Verify material against bill of lading description. Document in SM.
701.10 Micro -Silica Verify manufacturer on Concrete Plant Batch
Ticket is on Certified List for S 1045 maintained by OMM. Verify material against bill of lading description . Document in SM.
701.11 Ground Granulated
Blast Furnace Slag (GGBFS) Verify manufacturer on Concrete Plant Batch Ticket is on Certified List for S 1034 maintained by OMM. Verify material against bill of lading description . Document in SM.
701.13 Fly Ash Verify manufacturer on Concrete Plant Batch
Ticket is on Certified List for S 1026 maintained by OMM. Verify material against bill of lading description . 700.00 690 Document in SM If high LOI fly ash verify manufacturer on Concrete Plant Batch Ticket is on List for S 1115.
702.01 Asphalt Binder Certified asphalt PG binder: As directed by
OMM . Plant: Minimum of one sample per project per season, except for inconsequential quantities. Non-Certified PG binder: Sample and Approve by OMM before use. Certified binder: Plant: Submit sample to OMM . Non-certified binder: Submit to OMM . Do not allow asphalt production until material is approved. 702.02 702.03 702.04 702.07
702.13 Cut Back Asphalt
Cut Back Asphalt Emulsions Emulsified Asphalts Asphalt Emulsion MWS SBR Asphalt Emulsion Certified material: At the refinery or source as directed by OMM . Project and/ or Plant: One sample per each 25,000 gallons. None for less than 300 gallons. Non-certified material: Will be sampled and approved by OMM before use.
702.13 Provide Certified Test Data per
specification requirements. Certified material: Submit to OMM . Non-certified material: Submit to OMM . Do not use until approved. 702.05
702.06 Asphalt Primer
Waterproofing Asphalt Waterproofing Verify type and brand name of material is on QPL at the time of use. Document in SM. If rejecting material because material non -performs or looks defective during use, notify District Testing and OMM Asphalt section.
702.16 Polymer Emulsified
Binder Type A: Certified Material. At the refinery or source as directed by OMM . Project and/ or Plant Sample per 422.10. Non-certified material is sampled and approved by OMM before use. Type B: Certified test data Type A: Certified material: Submit to OMM . Non-certified material: Submit to OMM . Do not use until approved .
702.17 Crack Sealant Material is pre -tested and approved.
Will be shipped with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM Asphalt section. Type 1 Type II Provide fibers listed on the QPL. Provide PG64 -22 conforming to 702.01 . Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM Asphalt section. Type III Provide fibers listed on the QPL. Provide PG64 -22 conforming to 702.01 . Type IV Provide materials listed on the QPL . 703.02 703.04 703.05
703.08 Coarse Aggregate Coarse Aggregate will have current
certification for use, and be supplied by a S1069 Pre-Qualified Producer/ Supplier. Verify material certification, and Pre-Qualified status by checking SM or by using the CMRS portal and gen erating a report for that source or district. Document in SM. 60 to 75 lb. Q A sample s are taken by District Testing at each Pre - Qualified source a minimum of three (3 ) times per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation. 703.02 703.03 703.04 703.05 703.06
703.10 Fine Aggregate Fine Aggregate will have current certification
for use, and be supplied by a S1069 Pre- Qualified Producer/ Supplier. Verify material certifica tion, and Pre-Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Document in SM. 30 to 40 lb. Q A sample s are taken by District Testing at each Pre - Qualified source a minimum of three (3) times per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation. 703.02 703.04
703.05 Dense Graded
Aggregate Dense Graded Aggregate will have current certification for use, and be supplied by a S1069 Pre-Qualified Producer/ Supplier. Verify material certification, and Pre-Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Document in SM. 90 to 100 lb. Q A sample s are taken by District Testing at each Pre - Qualified source a minimum of three (3) times per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation. 700.00 691 703.07 Materials Mineral filler Limestone Dust will be supplied by a S1069 Pre-Qualified Producer/Supplier . Verify Pre- Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. For Portland cement assure source is on Certified list for S 1028 . For inert mineral filler sample for gradation. Submit to District Testing. 703.11 Type 1 Type 2 Type 3 Structural Backfill for 611 Bedding and Backfill All 703.11 (Type 1, 2, & 3) shall be provided by a S1069 Pre -Qualified Producer/Supplier. Verify material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Document in SM. 40-100lb (depending on coarse, fine, or dense grade) QA sample s are taken by District Testing at each Pre -Qualified source a minimum of one (1) time per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation.
703.13 Coarse Aggregate
for Items 451 and 452 All materials shall be provided by a S1069 Pre-Qualified Producer/S upplier . Verify material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Document in SM. 240-300 lb QA (Freeze Thaw/Quality) samples are taken by District Testing once (1) every 2 to 4 years depending on certification and submitted to OMM for testing (this is additional to standard coarse aggregate t esting) . Sample at the project on an as need ed basis to address material problems or risks associated with quality or gradation.
703.14 Steel Slag
Aggregate for Non - Pavement Use All materials shall be provided by a S1069 Pre-Qualified Producer Supplier . Stockpile and sample each 2500 tons (2300 metric tons). Notify the District laboratory for inspection of sources and to obtain split samples. Test for expansion . Document in SM. Steel Slag less than 10 yrs old requires X -Ray Fluorescence for total percent MgO, and X -Ray Diffraction for total perc ent periclase. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation.
703.16 Suitable Materials
for Embankment Construction All materials shall be provided by a S1069 Pre-Qualified Producer/S upplier . Multiple aggregate types available. Follow the requirements of the individual material specification. Verify material certification, and Pre-Qualified status by checking SM or by using the CMRS portal and generating a report for that so urce or district. Document in SM. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation.
703.17 Dense Graded
Aggregate for Item 304 All materials shall be provided by a S1069 Pre-Qualified Producer/Supplier. Verify the material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. 90 to 100 lb. QA sample taken by District Testing at each source a minimum of (1 ) time per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation.
703.18 Aggregate for Items
410, 411, and 617 All materials shall be provided by a S1069 Pre-Qualified Producer/Supplier. Verify the material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. 90 to 100 lb. QA sample taken by District Testing at each source a minimum of (1) time per year. Sample at the project on an as needed basis to address material problems or risks associated with quality or gradation.
703.19 A Crushed Aggregate
Slope Protection and Filter Aggre gate for Dump Rock Fill All materials shall be provided by a S1069 Pre-Qualified Producer/Supplier. Verify the material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Sample and/or photograph with a scale for sizing on an as needed basis to address material problems or risks associated with quality or gradation. 700.00 692 703.19.B Dumped Rock Fill and Rock Channel Protection All materials shall be provided by a S1069 Pre-Qualified Producer/Supplier. Verify the material certification, and Pre -Qualified status by checking SM or by using the CMRS portal and generating a report for that source or district. Sample and/or photograph with a scale for sizing on an as needed basis to address material problems or risks associated with quality or gradation. 704.01 704.02
704.03 Block:
Brick Concrete Masonry Shale Verify type of material is on QPL at the time of use. Inspect for condition and defects. Document in SM . Notify District Testing if rejecting material. When material non -performs or looks defective during use reject material and sample 12 pieces representative of defect to OMM for QA follow -up.
705.01 Glass Fiber
Reinforced Polymer (GFRP) Dowel and Deformed Bars Certified test data from an accredited testing facility will accompany each shipment. Document in SM. Notify District Testing upon receipt of shipment.
705.03 Joint Filler
Preformed Verify type and brand name of material is on QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM . Notify District Testing if rejecting material. If material non -performs or looks defective during use send one (1) 1.5'x2.5' sample representative of defect to OMM for QA follow -up.
705.04 Joint and Crack
Sealer Hot Applied Material is pre -tested and approved. Will be shipped with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM Asp halt section for sampling requirements.
705.05 Burlap Cloth
Materials Inspect for condition, appearance and dimension. Documenting in SM is not required . Sample only if there is a question that material meets specification. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
705.06 Sheet Curing
Materials Inspect for condition, appearance and dimension. Documenting in SM is not required. Sample only if there is a quest ion that material meets specification. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
705.07 Concrete Curing
Compounds Verify type and brand name of material is on QPL at the time of use. Inspect for condition and appearance. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send one (1) quart sample representative of defect to OMM Cement and Concret e section for QA follow - up.
705.10 Air Entraining
Admixtures Verify type and brand name of material listed on Concrete Plant Batch Ticket is on QPL at the time of use. Document in SM. Storage: Admixtures should be stored at concrete producer in such a ma nner to permit easy access for proper identification in weather resistant units. Provide minimum QA sample of one (1) annually per concrete plant, each material, each company. Minimum sample size one (1) quart .
705.11 Preformed
Elastomeric Joint Sealer Verify type and brand name of material is on QPL at the time of use. Inspect for condition, appearance, dimension and manufacturer trademark. Document in SM . Notify District Testing if rejecting material because material non - performs or looks defectiv e during use.
705.12 Chemical
Admixtures for Concrete Verify type and brand name of material is on QPL at the time of use. Document in SM. Storage: Admixtures should be stored at concrete producer in such a manner to permit easy access for proper identif ication in weather resistant units. Provide minimum QA sample of one (1) annually per concrete 700.00 693 plant, each material, each company. Minimum sample size one (1) quart.
705.13 Neoprene Sheeting Verify type and brand name of material is on
QPL at time of use. Inspect for condition and appearance. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
705.15 High Molecular
Weight Methacrylate (HMWM) Verify type and brand name of material is on QPL at the time of use. Document in SM.
705.20 Non Shrink, Non
Metallic Materials Verify type and brand name of material is on QPL at the time of use. Ensure mixing is performed in acco rdance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM for sampling requirements.
705.21 Quick Setting
Concrete Mortar Verify type and brand name of material is on QPL at the time of use. Ensure mixing is performed in accordance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM for sampling requirements.
705.22 Non-shrink Mortar Verify manufacturer is on the Approved List
maintained by OMM. Ensure mixing is performed in accordance with manufact urer’s recommendations on the container. Make three (3) or more 3"x6" cylinders from keyway mix. Ship to OMM Concrete Section. Document in SM. Sample will be tested at 3, 7 and 28 days. Do not open structure to traffic until a compressive strength of 5000 psi (34.5 MPa) is achieved.
705.23 A Epoxy -urethane
Sealers Verify type and brand name of material is on QPL at the time of use. Ensure mixing is performed in accordance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
705.23 B Non Epoxy Sealers Verify type and brand name of material is on
QPL at the time of use. Ensure mixing is performed in accordance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
705.24 Soluble Reactive
Silicate Verify type and brand name of material is on QPL at the time of use. Ensure mixing is performed in accordance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material.
705.25 Gravity Fed Resin Verify type and brand name of material is on
QPL at the time of use. Ensure mixing is performed in accordance with manufacturer’s recommendations on the container. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
705.26 Epoxy injection
Resin Verify type and brand name of material is on QPL at the ti me of use. Make sure that ports are properly installed and ensure mixing is performed in accordance with manufacturer’s recommendations Document in SM. Notify District Testing if rejecting material.
706.01 Non-Reinforced
Concrete Pipe Assure products are supplied by a source on the Certified List for S 1074 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. If rejecting material because material non -performs or looks defective during use, notify District Testing and OMM Cement and Concrete section . 700.00 694 Document in SM.
706.02 Reinforced Concrete
Circular Pipe Assure products are supplied by a source on the Certified List for S 1074 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, no tify District Testing and OMM Cement and Concrete section .
706.03 Reinforced Concrete
Pipe, Epoxy Coated Assure products are suppli ed by a source on the Certified List for S 1074 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, n otify District Testing and OMM Cement and Concrete section .
706.04 Reinforced Concrete
Elliptical Culvert, Storm Drain and Sewer Pipe Assure products are supplied by a source on the Certified List for S -1074 maintained by OMM. Received with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, not ify District Testing and OMM Cement and Concrete section .
706.05 Precast Reinforced
Concrete Box Sections Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or look s defective during use, not ify District Testing and OMM Cement and Concrete section . 706.051 Precast Reinforced Concrete Three -Sided Flat Topped Culverts Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, no tify District Testing and OMM Cement and Concrete section . 706.052 Precast Reinforced Concrete Arch Sections Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, no tify District Testing and OMM Cement and Concrete section . 706.053 Precast Reinforced Concrete Round Sections Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, not ify District Testing and OMM Cement and Concrete section .
706.06 Perforated Concrete
Pipe Assure products are supplied by a source on the Certified List for S 1074 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non-performs or looks defective during use, no tify District Testing and OMM Cement and Concrete section .
706.07 Concrete Drain Tile Assure products are supplied by a source on
the Certified List for S 1074 maintained by OMM. Receive with TE -24. Check d imension, markings, roughness or excessive cracks. Document in SM. If rejecting material because material non -performs or looks defective during use, notify District Testing and OMM Cement and Concrete section .
706.08 Vitrified Clay Pipe Verify type and brand name of material is on
QPL at the time of use. If rejecting material because material non -performs or looks defective during use, not ify 700.00 695 Inspect for condition, appearance and dimension. Document in SM. District Testing and OMM Cement and Concrete s ection .
706.09 Clay Drain Tile Verify type and brand name of material is on
QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM. If rejecting material because material non -performs or looks defective during use, no tify District Testing and OMM Cement and Concrete section .
706.10 Asphalt pipe joint
filler Verify type and brand name of material is on QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM. If rejecting material beca use material non -performs or looks defective during use, notify District Testing and OMM Asphalt section .
706.11 Resilient and
Flexible Gasket Joints Verify type and brand name of material is on QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM . Notify District Testing and OMM Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
706.12 Resilient and
Flexible Joints Verify type and brand name of material is on QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM . Notify District Testing and OMM Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
706.13 Precast Reinforced
Concrete Manhole Riser Sections, Catch Basins and Inlet Tops, and Temporary Barriers Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. Notify District Testing and OMM Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
706.14 Flexible Plastic
Gaskets Verify type and brand name of m aterial is on QPL at the time of use. Inspect for condition, appearance and dimension. Document in SM . Notify District Testing and OMM Cement and Concrete section, if rejecting material because material non-performs or looks defective during use. 706.1 5 Precast Reinforced Concrete Outlets Assure products are supplied by a source on the Certified List for S 1073 maintained by OMM Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Document in SM. Notify District Testing and OMM Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
707.01 Metallic Coated
Corrugated Steel Conduits and Underdrains [½ inch and 1/4 depth corrugations] Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defe ctive during use.
707.02 Metallic Coated
Corrugated Steel Conduits [1 inch depth corrugation] Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.03 Structural Plate
Corrugated Steel Structures Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective dur ing use.
707.04 Precoated,
Galvanized Steel Culverts Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and cracks. Document in SM. Notify Dist rict Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use . 707.05
705.07 Bituminous Coated
Corrugated Steel Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Notify Distri ct Testing and OMM Structural Welding and Metals section, if rejecting material 700.00 696 Pipe and Arches with Paved Invert [½ inch depth corrugations] [1 inch depth corrugations] Receive with TE -24. Check dimensions and markings. Document in SM. because material non -performs or looks defective during use.
707.10 Steel Tubing
Square and Rectangular Generally a fabricated component received with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.11 Mortar Lined
Corrugated Steel Pipe [any corrugation depth] Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM . Notify District Testing and O MM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.12 Corrugated Steel
Spiral Rib Conduits Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use 707.13
707.14 Bituminous Lined
Corrugated Steel Pipe [½ depth corrugations] [1 depth corrugations] Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.15 Corrugated Steel
Box Culverts Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting ma terial because material non -performs or looks defective during use.
707.18 Polymer Precoated,
Galvanized Steel Conduits with precoated galvanized smooth steel interior liner Products will be supplied by a source on the Certified List for S 1019 maintaine d by OMM. Receive with TE -24. Check dimension and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.19 Aluminum Coated
Steel Conduits with precoated galvanized smooth steel interior liner Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimension and markings. Document in SM. Notify District Testing and O MM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.20 Galvanized Coated
Steel Conduits with precoated galvanized smooth steel interior liner Products will be supplied by a sour ce on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimension and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.21 Corrugated
Aluminum Alloy Conduits and Underdrains [1/4, 7/16 & ½ inch depth corrugations] Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimension and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.22 Corrugated
Aluminum Alloy Conduits Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimension and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.23 Aluminum Alloy
Structural Plate Conduits Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Notify District Testin g and OMM Structural Welding and Metals section, if rejecting material 700.00 697 Receive with TE -24. Check dimensions and markings. Document in SM. because material non -performs or looks defective during use.
707.24 Corrugated
Aluminum Spiral Rib Conduits Products will be supplied by a sou rce on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.25 Corruga ted
Aluminum Box Culverts Products will be supplied by a source on the Certified List for S 1019 maintained by OMM. Receive with TE -24. Check dimensions and markings. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. 707.31 707.32
707.33 Polyethylene
Corrugated Pipe Products will be supplied by a source on the Certified List for S 1066 maintained by OMM. Receive with TE -24. Check dimension and markings. Document in SM.. Notify District Testing and OMM Asphalt section, if rejecting material because material non - performs or looks defective during use. 707.34
707.35 Polyethylene Pipe -
Outside Diameter Polyethylene Profile Wall Pipe Signed Letter of Certification from Supplier Notify District Testing and OMM Asphalt section, if rejecting material because material non - performs or looks defective during use.
707.41 Smooth -Wall
Polyvinyl Chloride Underdrain Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.42 Polyvinyl Chloride
Corrugated Smooth Interior Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective durin g use.
707.43 Polyvinyl Chloride
Profile Wall Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.45 Polyvinyl Chloride
Solid Wall Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.46 Polyvinyl Chloride
Drain Waste and Vent Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify D istrict Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.47 ABS and Polyvinyl
Chloride Composite Pipe Furnish certified test data conforming to
101.03 to the Engineer.
Document in SM. Accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data. Notify District Testing if rejecting material.
707.48 Polyvinyl Chloride
Large -Diameter Solid Wall Pip e Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.51 ABS D rain Waste
and Vent Pipe Furnish certified test data conforming to
101.03 to the Engineer.
Document in SM. Accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data. Notify Distric t Testing if rejecting material. 700.00 698 707.52 ABS Sewer Pipe Furnish certified test data conforming to
101.03 to the Engineer.
Document in SM. Accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data. Notify District Testing if rejecting material.
707.62 Polypropylene
Corrugated Single Wall Pipe Furnish a letter of certification documenting the material meets specification requirements .Document in SM. Accept based on inspection o f material for type, condition, dimension, receipt and verification of manufacturer’s certified test data. Notify District Testing if rejecting material.
707.65 Polypropylene
Corrugated Double Wall Pipe Furnish a letter of certification documenting the material meets specification requirements . Document in SM Accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data. Notify District Testing if rejecting material.
707.69 Polypropylene
Corrugated Tripe Wall Pipe Furnish a letter of certification documenting the material meets specification requirements . Document in SM. Accept based on inspection of material for type, condition, dimension, receipt and verification of manufa cturer’s certified test data. Notify District Testing if rejecting material.
707.70 Welded and
Seamless Steel Pipe Verify type and brand name of material is on QPL at the time of use. Document in SM. Notify District Testing and O MM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
707.80 Reinforced
Thermosetting Resin Pipe Accept based on inspection of material for type, condition, dimension, receipt and verification of manufact urer’s certified test data. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
708.01 Inorganic Zinc
Silicate Primer Paint Products w ill be supplied by a source on the Certified List for S 1084 maintained by OMM. Verify type and brand name of material is on QPL at the time of use. Inspect material container for markings, expiration date and condition. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use. Obtain a 1 qt (1 L) sample representative of the defects. 708.02 708.02B 708.02C 708.02D OZEU Structural Steel Pant Organic Zinc Pr ime Coat Epoxy Intermediate Coat Urethane Finish Coat Products will be supplied by a source on the Certified List for S 1084 maintained by OMM. Verify type and brand name of material is on QPL at the time of use. Inspect material container for markings, expiration date and condition. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use. Obtain a 1 qt (1 L) sample representative of the defects.
709.01 Deforme d and Plain
Billet Steel Bars for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OM M Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by OMM .
709.03 Rail Steel D eformed
and Plain Bars for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples 700.00 699 of each rebar size, with markings, and submit for QA testing by OMM .
709.05 Axle Steel
Deformed and Plain Bars for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by OMM .
709.08 Cold -Drawn Steel
Wire for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Received with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each diameter and submit for QA testing by OMM .
709.09 Fabricated Steel Bar
or Rod Mats for Concrete Reinforce ment Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM Notify District Testing and OMM Structural Welding and Metals section, if rejectin g material because material non -performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by OMM .
709.10 Welded Steel Wire
Fabric for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM . Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by OMM .
709.11 Deformed Steel
Wire for Concrete Reinforcement Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive wi th TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) o f the mat and submit for QA testing by OMM .
709.12 Welded Deformed
Steel Wire Fabric for Concrete Reinforcement Products will be supplied by a source on the Certified List for S -1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
709.13 Coated Dowel Bars Products will be supplied by a source on the
Certified List for S -1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural We lding and M etals section, if rejecting material because material non -performs or looks defective during use. Obtain 3 dowel bars and submit for QA testing by the Laboratory.
709.14 Epoxy -Coated Steel
Wire and Welded Wire Fabric for Reinforcement Products will be supplied by a source on the Certified List for S -1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting ma terial because material non -performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory. 700.00 700 709.15 Plastic Supports for Reinforcing Steel Products will be supplied by a source on the Approved List maintained by OMM. Inspect for dimension and condition. Notify District Testing if rejecting material that non -performs or looks defective during use.
709.16 Galvanizing Steel
Option for Bridge Spirals Products will be supplied by a source on the Certified List for S 1068 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by the Laboratory.
710.01 A
710.01 B
Barbed Wire Products will be supplied by a source on the Certified List for S 1067 mainta ined by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain a 5 ft (1.5 m) length of barbed wire and submit for QA testing by the Laboratory.
710.02 Woven Steel Wire
Fence, Type 47 Products will be supplied by a source on the Certified List for S 1067 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain 4 ft (1.2 m) width of fencing and submit for QA testing by th e Laboratory.
710.03 Chain -Link Fence
[ including Fittings and Accessories] Products will be supplied by a source on the Certified List for S 1067 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain samples as directed by the Laboratory.
710.06 Deep Beam Rail
Products will be supplied by a source on the Certified List for S 1042 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain a section of guardrail, three (3) 1 ft (0.3 m) l ong and submit for QA testing by the Laboratory.
710.09 Wire Rope Rail Inspect for dimension, condition, appearance
and markings on tag or reel. Submit one (1) six (6) ft. sample to OMM. Document in SM Approval required prior to use. Notify District Testing and OMM.
710.11 Fence Posts and
Braces [Lumber] [Steel] Products will be supplied by a source on the Certified List for S 1067 and S 1072 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
710.12 Square -Sawed and
Roun d Guardrail Posts Products will be supplied by a source on the Certified List for S 1042 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
710.14 Pressure Treated
Guardrail and Fence Posts, Braces, and Blocks Products will be supplied by a source on the Certified List for S 1042 and S 1067 maintained by OMM. Receive with TE -24. Check dimension, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and etals section, if rejecting material because material non -performs or looks defective during use.
710.15 Steel Guardrail
Posts Products will be supplied by a source on the Certified List for S 1042 maintained by OMM. Receive with TE -24. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material 700.00 701 Check dimension, markings and condition. Document in SM. because material non -performs or looks defective during use.
710.16 Guard Posts Products will be supplied by a source on the
Certified List for S 1042 and S 1067 maintained by OMM. Receive with TE -24. Check dimen sion, markings and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. 711.01 Structural Steel Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by OMM. Structural Steel Members are received with TE-24. If questions concerning structural steel materials, contact OMM Structural Steel Section and notify District Testing. 711.02 Galvanized Steel Any material supplied with galvanizing will conform to this specification. Randomly inspect galvanizing for appearance and thickness of coating. Notify District Testing if rejecting material. 711.03 Steel for Sheet Piling Certified Mill Test Data required for new material. Verify tensile and chemical properties meet requirements. Inspect all material for dimension and condition. Used material is not acceptable for permanent installations. Document field inspection. 711.0 4 Cold Rolled Steel Contact OMM Structural Steel section for acceptance process. Document in SM. Notify District Testing and OMM Structural Steel S ection section if rejecting material.
711.07 Steel Castings Contact OMM Structural Steel section for
acceptance process. Document in SM. Notify District Testing and OMM Structural Steel S ection section if rejecting material. 711.08 Arc-welding Electrode & Fluxes Verify manufacturer is on Approved List maintained by OMM. Inspect for dimension, condit ion and markings. If material is not on Approved List, certification and test data from supplier will be submitted to OMM. Do not use until approval has been received. 711.09 High Strength Bolts Nuts and Washers Receive with TE -24. Inspect material for dimension, condition and markings. Reject defective material. Perform field testing of assembly combination per S 1080. Document field inspection & testing in SM. If field test does not meet requirements of S 1080, retest bolt, nut and washer combination after application of a lubricant. Notify District Testing if rejecting material. 711.10 Machine Bolts General specification for many common bolts Verify material is component of certified supplier shipment like S1042 for Guardrail Suppliers or S1067 for Fence Suppliers. Inspect for condition and coating. Reject defective material. Notify District Testing if rejecting material. 711.12 711.13
711.14 Gray Iron Castings
Ductile Iron Castings Gray Iron & Ductile Iron Castings Verify manufacturer is on Appro ved List maintained by OMM. Receive with TE -24. Inspect for condition and defect. Document in SM. Notify District Testing if rejecting material . 711.15 711.16 711.17 711.18
711.19 Sheet Copper
Phosphor Bronze Plate Cast Bronze Leaded Bronze Sheet Lead Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by OMM. Structural Steel Members are received with TE-24. Document in SM. If questions concerning structural steel materials, contact OMM Structural Steel section and notify District Testing.
711.20 Aluminum for
Railings Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by O MM. If questions concerning structural steel materials, contact OMM Structural Steel Section and notify District Testing. 700.00 702 Structural Steel Members are received with TE-24. Document in SM.
711.21 Preformed Bearing
Pads Verify type and brand name of materi al is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. If material non -performs or looks defective during use notify District Testing and OMM.
711.22 Buried Liner
Waterproofing Membrane Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defects. Verify dimension conform to plan requirements. Document in SM. If material non -performs or looks defective during use notify District Testi ng and OMM. 711.23 Elastomeric Bearings Only accept elastomeric bearings shipped by TE-24.and provided by certified suppliers conforming to S1081. Notify district testing. to Inspect material to check location and number of internal shims utilizing an ice pick or similar tool. Five (5) Durometer Gage readings should be taken and averaged to determine compliance with design plans. Document in SM. Field acceptable for durometer. Reading average range: +/ - 7 points of design plan number.
711.24 Waterproofing
fabric Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing if rejecting material.
711.25 Type 2 Me mbrane
Waterproofing Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non-performs or looks defective during use send one (1) 4 ft2 sample representative of defect to OMM for QA follow -up.
711.26 Structural Timber,
Lumber and Piling Products will be supplied by a source on the Certified List for S1072 maintained by OMM. Received with TE -24 and supplier bill of lading. Check dimension, quantity and condition. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. 711.27 Prestressing Steel Material supplied by a Fabricator source on the Certified List for Items 515 maintained by OMM. Prestressed Concrete Members are received with TE -24. If questions concerning prstressed concrete or prestressed
711.28 Cellular Polyvinyl
Chloride Sponge Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send one (1) 1.5'x2.5' sample representative of defect to OMM for QA follow -up.
711.29 Type 3 Membrane
Waterproofing Verify type and brand name of material is on QPL at the time of use. Membrane primer is 705.04 material Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send one (1) 4 square ft sample representative of defect to OMM for QA follow -up.
711.30 Aluminum for Steps Verify type and brand name of material is on
QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. 700.00 703 711.31 Reinforced Propylene Plastic Manhole Steps Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
712.01 Expansion Shield
Anchors Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain three(3) samples representative of defect to OMM for QA follow -up.
712.02 Calcium Chloride
Verify type and brand nam e of material is on QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use contact OMM.
712.03 Sodium Chloride Inspect material for condition.
Submit one (1) pint sample per each Purchase Order to OMM. Document in SM. If additional samples required for material quantities exceeding 3000 tons, notify District Testing.
712.04 A Lime [ma sonry] Sample & Inspect material for condition with
24 hrs of receipt. One (1) five (5) lb sample. Document in SM. Notify District Testing if rejecting material.
712.04 B Lime [Quick] for
Stabilization Assure provided material is from suppliers certified under S 1087 and listed on the Departments QPL. Inspection for condition and defects Document in SM. If questions on material quality sample one (1) ten (10) lb sample of Quicklime. Send to Geotechnical Engineering. Notify District Testing if re jecting material. Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
712.04 C Lime Kiln Dust Assure provided material is from suppliers
certified under S1087 and documentation for S1087 is complete. Document in SM If qu estions on material quality , sample o ne (1) ten (10) lb sample of Lime Kiln Dust. Send to Geotechnical Engineering Notify District Testing if rejecting material. Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
712.06 Preservative
Treatment for Structural Timber Component material of pressure treated lumber. No approval required. Approval is for the wood including the preservative treatment If questions on pressure treated lumber check the specific material item and f ollow those instructions . 712.09 Geotextile Fabrics Verify type and brand name of material is on Approved List at the time of use. Inspect for condition and defect. Verify dimensions conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use submit one
712.10 Prefabricated Edge
Underdrain Inspect material for condition and dimension. Manufacturer’s certifie d test data required for acceptance. Document in SM. Notify District Testing if rejecting material. 712.11 Temporary Erosion Control Mats Material [Types A through I] Inspect material for condition and dimension. Manufacturer’s certified test data required for acceptance. Field Acceptance item . Notify District Testing if rejecting material.
712.12 Tied Concrete Block
Mat Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimensions conform to plan requirements. Document in SM. Notify District Testing and OMM Concrete section, if rejecting material because material non - performs or looks defective during use.
712.13 Articulating
Concrete Block Revetment System Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Notify District Testing and OMM Concrete section, if rejecting material because materia l non -700.00 704 Verify dimensions conform to plan requirements. Document in SM. performs or looks defective during use.
712.14 Detectable Warning
Device Verify type and brand name of material is on Approved List at the time of use. Inspect for condition and defect. Verify dimensions conform to plan requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use.
712.15 Geogrids Verify type and brand name of material is on
QPL at the time of use. Inspec t for condition and defect. Verify dimensions conform to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use submit one
720.01 Rectangular
Reflectors Verify type and brand name of material is on QPL at the time of use. Inspect for condition, color requirements and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use.
720.03 Flexible Delineator
Posts Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify dimensio n conform to plan requirements. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use.
721.01 Raised Pavement
Marker Castings Verify type and brand name of material is on QPL at the time of use. Inspect for condition and defect. Verify type conforms to pre -qualification requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because materi al non -performs or looks defective during use. Obtain one (1) 4x2x0.48 in. sample representative of defect to OMM for QA follow -up.
721.02 Prismatic
Retroreflector and Adhesive Verify type and brand name of material is on QPL at the time of use. Inspec t for condition and defect. Verify type conforms to pre -qualification requirements. Document in SM. Notify District Testing and OMM Structural Welding and Metals section, if rejecting material because material non -performs or looks defective during use. Obtain one (1) sample representative of defective RPM casting to OMM for QA follow -up.
721.03 Casting Adhesive Verify type and brand name of material is on
QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use. 725.02 Wire and Cables Verify type and brand name of material is on QPL at the time of use. Inspect for condition, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow - up.
725.03 Unit Type Duct -
Cable Systems Verify type and brand name of material is on QPL at the time of use. Inspect for condition, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a 10 ft. sample representative of non - compliance or defect to OMM for QA follow -up.
725.04 Rigid Ferrous Metal
Electrical Conduit and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition of coating and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a sample representative of non -compliance 700.00 705 or defect to OMM for QA follow - up. 725.051 Polyvinyl Chloride Conduit and Fittings Verify type and brand name of material is on QPL at the time of use . Inspect for condition, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow - up. 725.052 Polyethylene Conduit and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow - up.
725.06 Polymer Concrete
Pull Boxes Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow - up.
725.07 Plastic Pull Box Verify type and brand name of material is on
QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.08 Portland Concrete
Pull Boxes Products will be supplied by a source on the Certified List for S 1073 maintained by OMM. Receive with TE -24. Check dimension, markings, roughness or excessive cracks. Item 604 Installation documented on CA -P-3 Inspection Form. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.10 Junction Boxes Verify type and brand name of material is on
QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.11 B Lamps for
Luminaires Verify type and brand name of material is on QPL at the time of use. Inspect for condition, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.11 E Conventional
Luminaires for High Intensity Discharge Lamps (including Optical system, lamp, ballast and housing) Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requ irements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.11 F Wall Mounted
Underpass Luminaires (including Optical system, lamp, ballast and housi ng) Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.11 G High Mast/Low
Mast Luminaire (including Optical system, lamp, ballast and housing) Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.12 Polyethylene,
Fiberglas reinforced, Verify type and brand name of material is on QPL at the time of use. Notify District Testing if rejecting material . 700.00 706 Pull Box with Polymer concrete cover and support ring Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. If material non -performs or looks defective during use notify District Testing and OMM. 725.15B Fused Pull -Apart Connection Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 725.15C Unfused Pull -Apart Connection Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 725.15D Fused Bolted Connection Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejectin g material. If material non -performs or looks defective during use notify District Testing and OMM. 725.15E Unfused Permanent Connection Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
725.16 Ground Rods Verify type and brand name of material is on
QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use contact OMM. 725.19H Power Se rvice Components Wood Pole Products will be supplied by a source on the Certified List for S 1072 maintained by OMM. Received with TE -24 and supplier bill of lading. Check dimension, quantity and condition. Document in SM. Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non -performs or looks defective during use.
725.20 Multiple Cell
Polyvinyl Chloride Conduit and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, markings and conformance to plan requirements. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 725.21A Luminaire Supports Light Poles Verify pole provided by Certified Manufacturer under Supplement 1091. Inspect material for condition and conformance to plan requirements. Accept with TE -24 Document in SM Notify District Testing if rejecting material. If ma terial non -performs or looks defective during use notify District Testing and OMM. 725.21B Luminaire Supports Light Towers Inspect material for condition and conformance to plan requirements. Verify pole provided by Certified Manufacturer under Supplement 1091. Accept with TE -24. Document in SM Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 725.21B9 Luminaire Support Anchor Bolts OPTION 1 Verify type and brand name of material is on QPL at the time of use. Inspect for condition, and conformance to plan requirements. OPTION 2 Verify pole provided by Certified Manufacturer under S 1091. Accept with TE -24. Document in SM Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
726.01 Barrier Reflectors Verify type and brand name of material is on
QPL at the time of use. Inspect for condition and defect. Verify dimension conform to plan requirements. Document in SM. Notify District Testing and OMM Chemical section, if rejecting material because material non - performs or looks defective during use. 700.00 707 730.01 Steel Tube and Pipe This item typically is a comp onent of a sign support. Inspect total component for condition and conformance to shop drawings. Document in SM. Notify District Testing if rejecting material. 730.015 U-Channel Posts Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District testing and OMM. 730.016 Square Posts Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing an d OMM. 730.017 Wooden Box Beams Contact OMM Structural Steel section for acceptance process. Document in SM. Notify District Testing and OMM Structural Steel section if rejecting material.
730.02 Steel Anchor Bolts
and Nuts OPTION 1 Verify type and brand name of material is on QPL at the time of use. Inspect for condition, and conformance to plan requirements. OPTION 2 Verify pole provided by Certified Manufacturer under S 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.03 Steel Poles and
Arms Component material provided by Certified Manufacturer under Supplement 1093. Verify manufacturer is on 1093. Accept w ith TE -24. Document in SM Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.04 Base and Arm Plates Component material provided by Certified
Manufacturer under Supple ment 1093. Verify manufacturer is on 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.05 Handhole Covers Component material provided by Certified
Manufacturer under Supplement 1093. Verify manufacturer is on 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.06 Pole Caps Component material provided by Certified
Manufacturer under Supplement 1093. Verify manufacturer is on 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non-performs or looks defective during use notify District Testing and OMM.
730.07 Arm Caps Component material provided by Certified
Manufacturer under Supplement 1093. Verify manufacturer is on 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.08 Steel Hardware Component material provided by Certified
Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.09 Stainless Steel Component material provided by Certified
Manufa cturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.10 Stainless Steel
Hardware Component material provided by Certified Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093 Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 700.00 708 730.11 Aluminum Sheet and Plate Component material provided by Certified Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.12 Aluminum
Extrusions Component material provided by Certified Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.13 Aluminum Tube and
Pipe Com ponent material provided by Certified Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.14 Aluminum Castings Component material provided by Certified
Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.15 Aluminum Forgings Component material provided by Certified
Manufacturer under Supplement 1092 or 1093. Verify manufacturer is on 1092 or 1093. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.16 Aluminum Welding
Rods Normally only applies to shop fabrication. If performing field aluminum welding contact District Testing and OMM for recommendations. Notify District Testing if rejecting material.
730.17 Aluminum
Hardware Component material provided by Certified Manufacturer under Supplement 1092. Verify manufacturer is on 1092. Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.18 Reflectiv e Sheeting
Type F Use if certification provided. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.19 Reflective Sheeting
Type G Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 730.191 Reflective Sheeting Type G reboundable Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non-performs or looks defective during use notify District Testing and OMM. 730.192 Reflective Sheeting Type H Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 730.193 Reflective Sheeting Type J Verify type and brand name of material is on QPL at the time of use. Inspect for confo rmance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.20 Nonreflective
Sheeting Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
730.22 Silk Screen Inks No field acceptance requirements. - part of
730.19,191,192 or 193 items. 700.00 709 730.23 Transparent Electronic Cuttable Films No field acceptance requirements. - part of 730.19,191,192 or 193 items No field requirements. 731.03C Changeable Message Sign, Electrical Type Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective dur ing use notify District Testing and OMM.
731.05 Internally
Illuminated Fixed Message Sign Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
731.06 Sign Flasher
Assembly Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
731.07 School Speed Limit
Sign Assembly Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
731.08 Flexible Conduit Verify type and brand name of material is on
QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testi ng and OMM.
731.10 Timer with
Enclosure Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 732.01 Vehicular Signal Heads, Conventional Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify Di strict Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.02 Vehicular Signal
Heads, Optically Programmed, 12 - inch (300 mm) Lens Verify type and brand name of material is on QPL at t he time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.03 Vehicular Signal
Heads, Optically Programmed, 8 -inch (200 mm) Lens Provide Manufacturer’s Certification verify material meets specification requirements Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non-performs or looks defective during use notify District Testing and OMM.
732.04 C Vehicular and
pedestrian light Emitting Diode Lamps (LED) Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.05 Pedestrian Signal
Heads [Type A1] [Type A2] [Type D2] Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.06 Pedestrian
Pushbuttons Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective du ring use notify District Testing and OMM.
732.07 A Loop Detector Units
Nema TS 1 Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecti ng material. If material non -performs or looks defective during use notify District Testing and OMM. 700.00 710 732.07 B Loop Detector Units Nema TS 2 Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 732.07C Loop Detector Type 33x Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.08 Loop Detector
Units, Delay and Extension Type Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.11 Signal Supports Check provided by Certified Manufacturer
under Supplement 1094 Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.12 Strain Poles Check provided by Certified Manufacturer
under Supplement 1094 Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defectiv e during use notify District Testing and OMM. 732.13 Wood Poles Check provided by Certified Manufacturer under Supplement 1072 Accept with TE -24. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM. 732.14 Down Guy Assemblies Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if reject ing material. If material non -performs or looks defective during use notify District Testing and OMM.
732.15 Pedestals and Bases Verify type and brand name of material is on
QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.16 Conduit Risers See 725.04 requirements. Notify District Testing if rejecting
material. If materi al non -performs or looks defective during use notify District Testing and OMM.
732.17 Cable Support
Assemblies Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.18 Messenger and
Tether Wire Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.19 Cable and Wire Verify type and brand name of material i s on
QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
732.20 Power Service See 725.04 requirements Notify District Testing if rejecting
material. If material non -performs or looks defective during use notify District Testing and OMM.
732.21 Disconnect Switch
with Enclosure Verify type and brand name of material is on QPL at the time of use. Notify District Testing if rejecting material. 700.00 711 Inspect for conformance to dimension and condition. Document in SM. If material non -performs or looks defective during use notify District Testing and OMM.
733.02 C Controller Unit
Type TS2/A1 Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify Distri ct Testing and OMM.
733.02 D Controller Unit
Type TS2/A2 Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non-performs or looks defective during use notify District Testing and OMM.
733.02 E Controller Unit
Type 2070L Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.02 F Controller Unit
Type 2070 E Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.02 G Controller Unit
Type 2070LX Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.03 A Cabinet Type TS 1 Verify type and brand name of material is on
TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.03 B Cabinet Type TS 2 Verify type and brand name of material is on
TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting materia l. If material non -performs or looks defective during use notify District Testing and OMM.
733.03 C Cabinet Type 332 Verify type and brand name of material is on
TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.03 D Cabinet Type 334 Verify type and brand name of material is on
QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.03 E Cabinet Type 336 Verify type and brand name of materi al is on
TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.04 A Cabinet Riser for TS
1 – TS 2 cabinet Field inspect for 1/4 aluminum thickness and accept. Notify District Testing if rejecting material.
733.04 B Cabinet Riser for
Types 332, 334 or 336 Verify type and brand name of material is on QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.05 Flasher Controller Verify type and brand name of material is on
QPL at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.06 Controller, Master,
Traffic Responsive Assure the same manufacturer as the supplied controller unit 733.02. Notify District Testing if rejecting material. 700.00 712 733.07 Remote Monitoring Station Compatible with the supplied 733.02 and
733.06 unit. Notify District Testing if rejecting
material.
733.09 Uninterruptible
Power Supply (UPS) Verify type and brand name of material is on TAP at the time of use. Inspect for conformance to dimension and condition. Document in SM. Notify District Testing if rejec ting material. If material non -performs or looks defective during use notify District Testing and OMM.
733.09 C Battery System Verify type and brand name of material is on
TAP at the time of use. Inspect for conformance to dimension and condition. Docum ent in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
740.02 Traffic Paint Verify material is on Approved List
maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing .
740.03 Polyester Pavement
Marking Verify material is on Approved List maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing .
740.04 Thermoplastic
Pavement Marking Verify material is on Approved List maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing .
740.05 Preformed
Pavement Marking Verify material is on Approved List maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing .
740.06 Work Zone
Pavement Marking [Type 1 Removable] [Type 2 Non - Removable] Materials accepted by Engineer. Inspect material for uniform consistency. Document in SM. If rejecting for perf ormance provide 1 qt (1 L) sample and notify District.
740.07 Epoxy Pavement
Marking Material Verify material is on Approved List maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing.
740.08 Heat -Fused
Preformed Plastic Pavement Marking Material Verify material is on Approved List maintained by OMM. Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM. If rejecting for performance provide 1 qt (1 L) sample and notify District Testing.
740.09 A Glass Beads – for
740.02 Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM.
740.09 B Glass Beads – for
740.03 Accepted with TE -24.
Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM.
740.09 C Glass Beads – for
740.04 Accepted with TE -24.
Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM.
740.09 D Glass Beads – for
740.07 Verify material is on Approved List
main tained by OMM. 700.00 713 Accepted with TE -24. Inspect container for appropriate markings. Inspect material for uniform consistency. Document in SM.
748.01 Ductile Iron Pipe,
Joints, and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.02 Polyvinyl Chloride
(PVC) Pi pe, Joints, and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.03 Polyethylene (PE)
Service Branches and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Docum ent in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.05 Copper Service
Branches and Fittings Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.06 Steel Pipe
Encasement Basis of acceptance is manufacturers certification containing documentation of domestic origin from manufacturer. Notify District Testing if rejecting material
748.07 Polyethylene
Encasement Verify manufacturer certification conforms to ANSI/AWWA C105/A2 1.5 Inspect condition, dimension, suitability for intended use. Notify District Testing if rejecting material.
748.08 Gate Valve and
Valve Box Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.09 Inserting Valve and
Valve Box Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.10 Cutting -in Sleeve,
Valve, and Valve Box Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.11 Tapping Sleeve,
Valve, and Valve Box Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for inten ded use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.12 Tapping Saddle and
Corporation Stop Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.13 Service Sto p and
Service Box Verify type and brand name of material is on QPL at the time of use. Inspect for condition, dimension, suitability for intended use. Document in SM. Notify District Testing if rejecting material. If material non -performs or looks defective during use notify District Testing and OMM.
748.14 Meter, Setting, Stop,
and Chamber Inspect for condition, dimension, suitability for intended use. Acceptance based on manufacturer’s statement of conformity.
748.15 Fire Hydrant Verify type and brand name of material is on
QPL at the time of use. Notify District Testing if rejecting material. 701.00 701 CEMENTITIOUS MA TERIALS
701.00 Acceptance . Provide cements meeting 701.01, 701.02, 701.04, 701.05,
701.07 and 701.09 and certified according to Supplement 1028; fly ash meeting
701.13 and certified according to Supplement 1026; ground, granulated blast
furnace slag meeting 701.11 and certified according to Supplement 1034; and micro silica meeting 701.10 and certified according to Supplement 1045 , without prior sampling, testing and approval by the Department. Lists for certifie d cement, fly ash, GGBFS and micro silica sources are maintained by the Laboratory.
701.01 Air -Entraining Portland Cement. Provide air -entraining portland
cement according to ASTM C 150, Type IA. The Gillmore time of set and the air permeability (finene ss) tests will govern.
701.02 Portland Cement. Provide portland cement according to ASTM C 150,
Type II. The Gillmore time of set and the air permeability (fineness) tests will govern.
701.04 Portland Cement. Provide portland cement according to ASTM C 150,
Type I. The Gillmore time of set and the air permeability (fineness) tests will govern.
701.05 High Early Strength Portland Cement. Provide high early strength
portland cement according to ASTM C 150, Type III. The Gillmore time of set test shall govern.
701.07 Masonry Cement. Provide masonry cement according to ASTM C 91.
701.09 Slag Modified Portland Cement. Provide slag modified portland
cement according to ASTM C 595, Type IS (< 25 ).
701.10 Micro -Silica. Provide micro -silica according t o ASTM C 1240. Do not
use micro -silica admixtures in dissolvable bags.
701.11 Ground Granulated Blast Furnace Slag (GGBF S). Provide ground
granulated blast furnace (GGBF S) according to ASTM C 989, Grade 100 minimum.
701.13 Fly Ash for Use in Portland Cement Concrete. Provide fly ash
according to ASTM C 618, Class C or F, except ensure a maximum loss on ignition (LOI) of 3 percent. Fly ash from sources certified according to Supplement 1026 and with an LOI greater than 3 percent may be approved for us e by the Department if the fly ash is treated with a chemical conforming to Supplement 1115. Inspect for condition, dimension, suitability for intended use. Document in SM If material non -performs or looks defective during use notify District Testing and OMM.