00815.90 857 Section 00815 - Bollards Description
00815.00 Scope - This Work consists of furnishing and installing bollards at locations shown or as
directed. Materials
00815.10 Materials - Furnish Material s meeting the following requirements:
Commercial Grade Concrete ...................................................................... 00440 Granular Drain Backfill .......................................................................... 00430.11 Reflective Sheeting (Type III and Type IV) .......................................... From QPL
00815.11 Posts and Sleeves - Use Schedule 40 steel pipe for the posts and either Schedule 40 or
Schedule 80 steel pipe for the sleeves , as shown. Use st eel pipe conforming to ASTM A53, Type E, Grade A.
00815.12 Plates, Shapes, Fasteners, and Hardware - Use plates and shapes conforming to
ASTM A36. Use fasteners and hardware conforming to ASTM A449.
00815.13 Galvanizing - Hot-dip galvanize all metal components after fabrication according to
AASHTO M 111 ( ASTM A123) or AASHTO M 232 ( ASTM A153), as applicable.
00815.14 PVC Pipe - Use Schedule 40 PVC pipe.
00815.15 Painting Bollards - Paint the exposed portion of designated bollards with one coat of the
type and color of coating, as shown or specified. Construction
00815.40 Bollards - Install bollards as shown or as directed.
Measurement
00815.80 Measurement - The quantities of bollards will be measured on a unit basis.
Payment
00815.90 Payment - The accepted quantities of bollards will be paid for at the Contract unit price,
per unit of measurement, for the following items: Pay Item Unit of Measurement
Get an email when 00815 changes
Oregon revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.