706PLUG AND CAP PIPE - ALL SIZES

RI · 2024 Standard SpecificationsBook pages 322322View official source ↗

7−16 706.02 MATERIALS. Plugs and caps for cast iron pipe shall be of the type approved by the utility company for a particular application.

a.Plugs and caps for vitrified clay pipe shall be of the type recommended for this purpose by the manufacturers of said pipe.
b.Cement or brick masonry plugs shall consist of approved cement or brick masonry units securely bedded with cement mortar.
c.Cement mortar shall conform to the requirements of Subsection M.04.03.5 of these Specifications. 706.03 CONSTRUCTION METHODS. The plugs described above shall be placed in all lines where indicated or directed when such lines are broken into during construction. All such plugs shall produce watertight joints. Plugs and caps installed in pressure lines shall be properly strapped and blocked to withstand the anticipated back pressure. Vitrified clay and cement or brick masonry shall be properly and securely set in place, blocked and protected to preclude infiltration or exfiltration due to hydrostatic pressure. 706.04 METHOD OF MEASUREMENT. "Plug and Cap Pipe All Sizes" will be measured by the number of each such unit actually installed regardless of the size or type. 706.05 BASIS OF PAYMENT. The accepted quantity of "Plug and Cap Pipe All Sizes" will be paid for at the contract unit price per each such unit as listed in the Proposal. The price so-stated is full and complete compensation for all labor, materials and equipment required to provide said plugs or caps and for all incidentals required to finish the work, complete and accepted by the Engineer. SECTION 707 ADJUST DRAINAGE AND UTILITY STRUCTURES

707.01 DESCRIPTION. This work consists of adjusting drainage structures, telephone, electrical,

and sanitary manholes to those new grades and details indicated on the Plans or as directed by the Engineer, all in accordance with these Specifications.

707.02 MATERIALS. Materials shall conform to the applicable paragraphs of Subsection 702.02.1;

Masonry Unit Construction , of these Specifications.