RIGHT-OF-WAY POLE FENCE

PART 1 GENERAL

1.1SECTION INCLUDES

A.Right-of-way pole fence.

1.2RELATED SECTIONS

A.Section 06055: Timber and Timber Treatment

1.3REFERENCES

A.American Wood Protection Association (AWPA) Book of Standards

1.4DEFINITIONS Not Used

1.5SUBMITTALS Not Used

PART 2 PRODUCTS

2.1UNTREATED WOOD POSTS FOR LINES, GATES, ENDS, AND CORNERS

A.Native juniper or approved equal.
B.Line posts must have a diameter of at least 6 inch.
C.All posts must be sound, free of decay or defects, and structurally suitable.

2.2TREATED WOOD POSTS AND WOOD POLE RAILS

A.Sound Douglas-fir, hemlock, or pine that is free from decay, splits, multiple

cracks, any other defect, and structurally suitable.

B.Round posts and pole rails
1.Round posts must have a diameter of at least 6 inch.
2.Round pole rails must have a diameter of at least 3 inch and no

greater than 6 inch.

3.No post or pole rail may deviate from a straight edge placed along

its length by more than ½ the diameter of the post or pole rail.

Right-of-Way Pole Fence

4.Taper (diameter differential) in round members must not exceed 2

inch in 10 ft.

5.Fabricate posts and pole rails before pressure treatment of the

wood members.

6.Treat posts and pole rails according to Section 06055.
7.Apply field treatment preservatives according to AWPA Standard

M4 after field drilling or cutting. Refer to AWPA Standard M4, Section 7 for accepted field treatment preservative systems.

8.Keep round posts and pole rails free of bark, protruding knots, or

other irregularities.

PART 3 EXECUTION

3.1PREPARATION

A.Clear and grade a minimum area to permit proper fence installation.

3.2INSTALLATION

A.Install Right-of-Way Pole Fence according to FG Series Standard

Drawings.

B.Compact backfill material around post to the density of the surrounding

ground.

C.Cut wood posts to the designated height and slant top at an approximate

30 degree angle.

END OF SECTION

Right-of-Way Pole Fence

Get an email when 02823 changes

Utah revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Utah Standard Specifications for Road and Bridge Construction, 2026 Edition. Pages 649–650 of 1,331. View official source ↗

Ask about this section

Scoped to Utah Standard Specifications, Section 02823 — Right-Of-Way Pole Fence. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.