Fire Code Egress Basics — IFC Chapter 10
Egress rules in the International Fire Code (Chapter 10) all start from one number, the occupant load, and then ask how many exits you need, how wide they must be, how far people must travel to reach one, and whether they can find it in the dark. Chapter 10 of the IFC tracks Chapter 10 of the International Building Code closely.
Worth knowing
- Occupant load is the number that drives everything else. If a tenant fit-out changes the use from storage to retail, the load, the exit count and the widths can all change with it.
- Chapter 10 does not apply to a house the way it does a store. One- and two-family dwellings follow the International Residential Code (egress windows, stairs and doors) instead, which is why residential and commercial answers online often disagree.
- The exact exit-count tables and travel-distance limits vary by occupancy group and sprinkler status. Look up the table for your group rather than relying on the typical figures here.
- The adopted edition matters. Section numbers were reorganized between the 2018, 2021 and 2024 editions, and state fire codes frequently amend Chapter 10.
- A fire code official, not this page, decides compliance on a specific building. For an existing building the fire code or the existing building code may apply instead of new-construction rules.
Common questions
What does the code say about occupant load for Fire Code Egress Basics?
Floor area divided by the occupant load factor for the use, using gross or net area as the table says; for example business areas count 150 sq ft gross per person and assembly space with tables and chairs counts 15 sq ft net per person. (IFC 1004.5, Table 1004.5)
What does the code say about number of exits for Fire Code Egress Basics?
Spaces and stories need at least two exits or exit access doorways once the occupant load or travel distance passes the single-exit limits in the tables; very large loads need three or four exits. (IFC 1006.2, 1006.3)
What does the code say about egress width for Fire Code Egress Basics?
Width is sized from occupant load: 0.3 in. per person for stairways and 0.2 in. per person for doors and other components, with lower factors allowed in sprinklered buildings that meet the conditions. (IFC 1005.3.1, 1005.3.2)
Adopted edition by state
Base-code year from BuildSpec’s adoption records. States often amend the base code, and your city or county may differ, so confirm with your building department. Fire codes are usually adopted by the state fire marshal or the local fire district; BuildSpec holds an IFC edition on record for only the states listed here.