B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Home / Arizona Permits / Phoenix

Building Permits in Phoenix, Arizona

City in Maricopa County
Verified August 2026
See Phoenix's fees, required documents and inspection sequence: free for 14 days, no card required.Sign inStart free trial

Adopted Construction Codes

These are the state-level code editions for Arizona. They apply in Phoenixunless a verified local adoption or amendment is noted — in local-adoption states, confirm the city or county's own code editions with the building department.

CodeEditionAdoption
IBC — International Building Code2018 IBC — BUT ONLY FOR FACTORY-BUILT BUILDINGS. ARIZONA HAS NO GENERAL STATEWIDE BUILDING CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW. For ordinary site-built construction there is no state-adopted IBC of any edition: adoption is entirely local and entirely permissive. The ONE statewide instrument in Arizona law that names the International Building Code is A.A.C. R4-34-102 (Board of Manufactured Housing / Office of Manufactured Housing, Arizona Department of Housing), which incorporates by reference "International Building Code (IBC), 2018 edition" published by the International Code Council. THE INCORPORATION IS FROZEN BY ITS OWN TERMS: R4-34-102 opens "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions" — so the 2018 IBC does NOT roll forward when ICC publishes a new edition; it stays 2018 until the Board amends the rule. Companion editions incorporated in the same rule: 2018 IRC, 2018 IMC, 2018 IPC, 2018 IFGC, 2018 IECC, 2017 NEC (NFPA), and FEMA P-85 "Protecting Manufactured Homes from Floods and Other Hazards", 2nd ed. (Nov 2009). Authority is A.R.S. s 41-4010(A)(13); the incorporation was last amended by final rulemaking at 26 A.A.R. 3327, EFFECTIVE JANUARY 31, 2021 (Supp. 20-4), which is the effective_date recorded. R4-34-603(A) and R4-34-705(A) route factory-built-building and accessory-structure construction to "applicable standards in R4-34-102". A future run should NOT read this row as "Arizona: 2018 IBC" — it is "Arizona: 2018 IBC for factory-built buildings only, and nothing statewide for anything else."A.A.C. R4-34-102 (Board of Manufactured Housing, incorporation by reference; authority A.R.S. s 41-4010(A)(13); amended by final rulemaking at 26 A.A.R. 3327, effective 1-31-2021, Supp. 20-4); no general statewide adoption — delegation left local by A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities, adoption by reference procedure); state-owned buildings exempt from local building codes by A.R.S. s 34-461 · source ↗
IECC — International Energy Conservation Code2018 IECC — BUT ONLY FOR FACTORY-BUILT BUILDINGS AND MANUFACTURED-HOUSING ACCESSORY STRUCTURES. ARIZONA HAS NO GENERAL STATEWIDE ENERGY CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW. For ordinary site-built residential and commercial construction there is no state-adopted IECC of any edition; adoption is entirely local and entirely permissive (A.R.S. s 11-861(A) counties, A.R.S. s 9-802 municipalities). The ONE Arizona rule that adopts a numbered IECC edition is A.A.C. R4-34-102(6) (Board of Manufactured Housing / Office of Manufactured Housing, Arizona Department of Housing), verbatim: "International Energy Conservation Code (IECC), 2018 edition, available from the International Code Council, 4051 Flossmoor Road, Country Club Hills, IL 60478 or iccsafe.org". THE INCORPORATION IS FROZEN BY ITS OWN TERMS: the rule opens "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions" — the 2018 IECC does NOT roll forward when ICC publishes a new edition. A future run must NOT read this row as "Arizona: 2018 IECC" — it is "Arizona: 2018 IECC for factory-built buildings only, and nothing statewide for anything else."A.A.C. R4-34-102(6) (Board of Manufactured Housing, incorporation by reference; authority A.R.S. s 41-4010(A)(13); amended by final rulemaking at 26 A.A.R. 3327, effective 1-31-2021, Supp. 20-4). No general statewide energy code: A.R.S. s 34-451(A) delegates edition-less standards for state capital projects to the Governor's energy office; adoption for all other construction is left local by A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities). · source ↗
IFC — 2024 IFCA.A.C. R4-36-201 (authority A.R.S. § 41-2146) · source ↗
IMC — International Mechanical Code2018 IMC — BUT ONLY FOR FACTORY-BUILT BUILDINGS AND MANUFACTURED-HOUSING ACCESSORY STRUCTURES. ARIZONA HAS NO GENERAL STATEWIDE MECHANICAL CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW. For ordinary site-built construction there is no state-adopted mechanical code of any kind and no edition of the IMC governs; adoption is entirely local and entirely permissive (A.R.S. s 11-861(A) counties, A.R.S. s 9-802 municipalities). The ONE Arizona rule that adopts a numbered IMC edition is A.A.C. R4-34-102(3) (Board of Manufactured Housing / Office of Manufactured Housing, Arizona Department of Housing), verbatim: "International Mechanical Code (IMC), 2018 edition, available from the International Code Council, 4051 Flossmoor Road, Country Club Hills, IL 60478 or iccsafe.org". THE INCORPORATION IS FROZEN BY ITS OWN TERMS: the rule opens "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions, and are available on the Board's website" — the 2018 IMC does NOT roll forward when ICC publishes a new edition; it stays 2018 until the Board amends the rule. A future run must NOT read this row as "Arizona: 2018 IMC" — it is "Arizona: 2018 IMC for factory-built buildings only, and nothing statewide for anything else."A.A.C. R4-34-102(3) (Board of Manufactured Housing, incorporation by reference; authority A.R.S. s 41-4010(A)(13); amended by final rulemaking at 26 A.A.R. 3327, effective 1-31-2021, Supp. 20-4), with exceptions at A.A.C. R4-34-103 (none applying to the IMC) and scope routing at R4-34-603(A), R4-34-605 and R4-34-705(A). No general statewide mechanical code: adoption is left local by A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities, adoption by reference procedure); state-owned buildings are exempt from local building codes by A.R.S. s 34-461; local jurisdictions may petition the Board for an exception under A.R.S. s 41-4010(D). · source ↗
IPC — International Plumbing Code2018 IPC — BUT ONLY FOR FACTORY-BUILT BUILDINGS AND MANUFACTURED-HOUSING ACCESSORY STRUCTURES. ARIZONA HAS NO GENERAL STATEWIDE PLUMBING CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW. For ordinary site-built construction there is no state-adopted plumbing code of any kind — no IPC, no UPC — and adoption is entirely local and entirely permissive (A.R.S. s 11-861(A) counties, A.R.S. s 9-802 municipalities). The ONE Arizona rule that adopts a numbered plumbing edition is A.A.C. R4-34-102(4) (Board of Manufactured Housing / Office of Manufactured Housing, Arizona Department of Housing), verbatim: "International Plumbing Code (IPC), 2018 edition, available from the International Code Council, 4051 Flossmoor Road, Country Club Hills, IL 60478 or iccsafe.org". THE INCORPORATION IS FROZEN BY ITS OWN TERMS: the rule opens "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions" — the 2018 IPC does NOT roll forward when ICC publishes a new edition. A future run must NOT read this row as "Arizona: 2018 IPC" — it is "Arizona: 2018 IPC for factory-built buildings only, and nothing statewide for anything else."A.A.C. R4-34-102(4) (Board of Manufactured Housing, incorporation by reference; authority A.R.S. s 41-4010(A)(13); amended by final rulemaking at 26 A.A.R. 3327, effective 1-31-2021, Supp. 20-4). No general statewide plumbing code: adoption is left local by A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities, adoption by reference procedure); state-owned buildings are exempt from local building codes by A.R.S. s 34-461. · source ↗
IRC — International Residential Code2018 IRC — BUT ONLY FOR FACTORY-BUILT BUILDINGS, MANUFACTURED-HOUSING RECONSTRUCTION AND ACCESSORY STRUCTURES. ARIZONA HAS NO GENERAL STATEWIDE RESIDENTIAL CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW. For an ordinary site-built Arizona house there is no state-adopted IRC of any edition; adoption is entirely local and entirely permissive (A.R.S. s 11-861(A) counties, A.R.S. s 9-802 municipalities). The ONE Arizona rule that adopts a numbered IRC edition is A.A.C. R4-34-102(2) (Board of Manufactured Housing / Office of Manufactured Housing, Arizona Department of Housing): "International Residential Code (IRC), 2018 edition". THE INCORPORATION IS FROZEN BY ITS OWN TERMS: R4-34-102 opens "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions, and are available on the Board's website" — the 2018 IRC does NOT roll forward when ICC publishes a new edition; it stays 2018 until the Board amends the rule. A future run must NOT read this row as "Arizona: 2018 IRC" — it is "Arizona: 2018 IRC for factory-built buildings only, and nothing statewide for a site-built house."A.A.C. R4-34-102(2) (Board of Manufactured Housing, incorporation by reference; authority A.R.S. s 41-4010(A)(13); amended by final rulemaking at 26 A.A.R. 3327, effective 1-31-2021, Supp. 20-4), as excepted by A.A.C. R4-34-103(A)(1) and (A)(2) (24 A.A.R. 1499, eff. 6-30-2018, Supp. 18-2). No general statewide residential code: adoption is left local by A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities, adoption by reference procedure); state-owned buildings are exempt from local building codes by A.R.S. s 34-461. · source ↗
NEC — National Electrical Code (NFPA 70)2017 NEC (NFPA 70) — BUT ONLY FOR FACTORY-BUILT BUILDINGS AND MANUFACTURED HOUSING. ARIZONA HAS NO GENERAL STATEWIDE ELECTRICAL CODE, AND THAT NEGATIVE IS THE PRIMARY FINDING ON THIS ROW — identical in shape to Arizona's existing IBC, IRC, IMC, IPC and IECC rows. ADOPTING TEXT VERBATIM, A.A.C. R4-34-102(7): "National Electrical Code (NEC), 2017 edition, available from the National Fire Protection Association, One Batterymarch Park, Quincy, MA 02169 or nfpa.org;" The section's opening sentence, VERBATIM, fixes the edition hard: "The following materials are incorporated by reference, apply to this Chapter, include no later amendments or editions, and are available on the Board's website." SO THE 2020 AND 2023 NEC HAVE NO FORCE UNDER THIS CHAPTER BY THE CHAPTER'S OWN WORDS — "no later amendments or editions". THE 2017 NEC IS NOW THE OLDEST ELECTRICAL EDITION RECORDED IN THIS TABLE AND IT IS ALSO OLDER THAN THE 2018 I-CODES SITTING BESIDE IT IN THE SAME LIST (R4-34-102(1)-(6)) — the Board took the 2018 I-Code family but the 2017, not the 2017-contemporaneous-or-later, NEC. ANYONE REPORTING ARIZONA AS A 2020-NEC OR 2023-NEC STATE IS WRONG TWICE: wrong edition, and wrong that the state adopts one at all for site-built work. FOR ORDINARY SITE-BUILT CONSTRUCTION, ELECTRICAL CODE ADOPTION IN ARIZONA IS LOCAL: A.R.S. s 11-861(A) (counties, permissive) and A.R.S. s 9-802 (municipalities, adoption-by-reference procedure); state-owned buildings are exempt from local building codes by A.R.S. s 34-461. SCOPE (applies_to left NULL — the column accepts only residential/commercial, and this covers both within the factory-built sector): the Chapter is the Board of Manufactured Housing's, A.A.C. Title 4 Ch. 34.A.A.C. R4-34-102(7) (Arizona Board of Manufactured Housing, materials incorporated by reference), authority A.R.S. s 41-4010(A)(13); current entry added/amended by final rulemaking at 26 A.A.R. 3327, effective January 31, 2021 (Supp. 20-4). HISTORICAL NOTE on R4-34-102, VERBATIM: "Adopted effective January 31, 1979 (Supp. 79-1). Amended effective May 28, 1980 (Supp. 80-3). Amended effective October 20, 1981 (Supp. 81-5). Former Section R4-34-102 renumbered to R4-34-103, new Section R4-34-102 renumbered from R4-34-101 and amended effective July 3, 1991 (Supp. 91-3). Amended effective September 3, 1992 (Supp. 92-3). Section repealed by final rulemaking at 6 A.A.R. 47, effective December 8, 1999; new Section adopted by final rulemaking at 6 A.A.R. 145, effective December 8, 1999 (Supp. 99-4). Amended by final rulemaking at 11 A.A.R. 464, effective March 5, 2005 (Supp. 05-1). Amended by final rulemaking at 18 A.A.R. 944, effective June 4, 2012 (Supp. 12-2). Amended by final rulemaking at 24 A.A.R. 1499, effective June 30, 2018 (Supp. 18-2). Amended by final rulemaking at 26 A.A.R. 3327, effective January 31, 2021 (Supp. 20-4)." Exceptions section A.A.C. R4-34-103 (no electrical exception). No general statewide electrical code: A.R.S. s 11-861(A), A.R.S. s 9-802, A.R.S. s 34-461. · source ↗
How much does a permit cost in Phoenix? →
Published fee amounts by permit type, how Phoenix calculates them, plan review and surcharges — quoted from the official fee schedule.
Permit checklists by project →
Deck, fence, shed, water heater and more — whether Phoenix requires a permit, what to submit, which inspections it publishes, and what it charges. Every line quoted from a Phoenix document.

Permit Requirements

building permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
deck permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
electrical permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
fence permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
reroof permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
retaining wall permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
shed permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
water heater permit
Phoenix specifics
Fees, required documents and the inspection sequence is available to BuildSpec members. Sign inStart free 14-day trial
Ask BuildSpec AI about Phoenix

Get a plain-English answer grounded in this page’s verified data — e.g. “Do I need a permit for a 180 sq ft shed in Phoenix?”

Ask Code AI →
Have a specific address?

Get a printable permit report for any address — jurisdiction, adopted codes, exemption rules, and who to call, on one page.

Get an Address Report →

Related on BuildSpec

Arizona adopted codes →Arizona DOT specifications →Code calculators →