Home / Products / Div 08 — Openings / Smooth-Star Fiberglass Entry Door
Therma-TruFiberglass doorDiv 08 · OpeningsNo manufacturer photo on file
Div 08 · Openings

Smooth-Star Fiberglass Entry Door

T
Therma-Tru · Smooth-Star (collection). PRIOR MODEL "Smooth-Star S-2000" WITHDRAWN: no page or document retrieved 2026-09-12 carries an S-2000 designation, and the collection page publishes NO model or series number at all. The seed string is unverifiable and was removed rather than left standing.

A paint-grade fiberglass entry door collection. Therma-Tru own 3-part specification describes the Smooth-Star face sheet as a proprietary fiberglass-reinforced thermoset composite of 1/16 inch minimum thickness - the same construction it gives Fiber-Classic, and thinner than the 3/32 inch minimum it gives Classic-Craft. The collection page presents it as a ready-to-paint, smooth-surfaced alternative to a steel door. Written by BuildSpec from the manufacturer retrieved pages; no marketing copy reproduced.

ENERGY STARContributes to 2 LEED credits
Compiled from public manufacturer data and not yet verified against a primary source. Confirm against the manufacturer\u2019s current datasheet before specifying.

Specifications

R-Value~R-5
U-Factor0.17 with glass
CorePolyurethane foam

Certifications & Standards

ENERGY STAR
WDMA I.S.7
Attributes — product claims, not third-party certifications
ADA compliant

Sustainability

LEED Contribution
MR: Building Product Disclosure & Optimization · MR: Sourcing of Raw Materials
ENERGY STAR
Certified

Code sections

Sections of the model codes that address this type of product. A link opens the code library at the chapter that holds the section. It points to the code; it does not say this model meets it.

  • undefined 2021 C402.5.4Maximum air leakage rate for fenestration assemblies

    Table C402.5.4 sets a maximum air leakage rate for swinging doors and names the test procedure as AAMA/WDMA/CSA 101/I.S.2/A440 or NFRC 400, with ASTM E283 at 1.57 psf named for curtain walls. The manufacturer 3-part specification for this product cites NFRC 400 and ASTM E283 by designation in its Part 1.3 references. Both ends are documents we retrieved and both name the same test procedures. THIS RECORDS THAT THE PRODUCT IS SPECIFIED AGAINST THE PROCEDURE THE CODE NAMES. IT DOES NOT ASSERT THAT SMOOTH-STAR MEETS THE 0.20 CFM/FT2 LIMIT, because the manufacturer publishes no tested rate - obtaining one is the first ask of the outreach letter.

Applies to Code Sections

Code sections where this product or product category is relevant. Click through to the viewer for full text and commentary.

IECC 402