§ 56.14132 — Horns and backup alarms

Subpart M — Machinery and Equipment

(a)Manually-operated horns or other audible warning devices provided on self-propelled mobile equipment as a safety feature shall be maintained in functional condition. (b)(1) When the operator has an obstructed view to the rear, self-propelled mobile equipment shall have—

(i)An automatic reverse-activated signal alarm;

(ii)A wheel-mounted bell alarm which sounds at least once for each three feet of reverse movement;

(iii)A discriminating backup alarm that covers the area of obstructed view; or

(iv)An observer to signal when it is safe to back up.

(2)Alarms shall be audible above the surrounding noise level.

(3)An automatic reverse-activated strobe light may be used at night in lieu of an audible reverse alarm.

(c)This standard does not apply to rail equipment.