B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
30 CFR Part 56Public Domain

§ 56.6401 — Shunting

Subpart E — Explosives

Except during testing—

(a)Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round;

(b)Wired rounds shall be kept shunted until connected to the blasting line; and

(c)Blasting lines shall be kept shunted until immediately before blasting.

Public Domain: 30 CFR Part 56 (MSHA Safety and Health Standards — Surface Metal and Nonmetal Mines) is a U.S. government publication and is not subject to copyright. Text extracted from the official source ↗. Figures are served from the eCFR; if one does not load, use the link in its place.
MSHA Part 56 56.6401 — Shunting | BuildSpec